Product Series: CH (Cable Harness / Motor Lead Wire Assembly)
Product Introduction:
The CH092A-11-1105 is a pre-assembled motor power cable with connectors, specifically engineered for Kollmorgen servo motors. It provides a factory-terminated, tested, and shielded connection between the servo drive and the motor, ensuring signal integrity and compliance with EMC standards.
Detailed content
Model Breakdown:
- CH = Cable Harness Series
- 092A = Cable Cross-Section: 9.2mm² (AWG 8 equivalent)
- 11 = Connector Type Code (M23 or MS-style connector variant)
- 1105 = Length Code: 5 meters
Technical Specifications:
| Parameter | Value |
|---|---|
| Conductor Cross-Section | 9.2 mm² (3× 9.2mm² + 2× 0.75mm² for brake) |
| Cable Length | 5.0 meters (drive end to motor end) |
| Voltage Rating | 300V / 500V AC/DC |
| Current Rating | 48A continuous (per phase) |
| Shielding | Double-shielded (Braid + Foil) |
| Outer Jacket Material | PUR (Polyurethane) — Oil and Abrasion Resistant |
| Temperature Range | -20°C to +80°C (flexing) / -40°C to +105°C (fixed) |
| Connector (Drive End) | M23 23-pin (or 17-pin depending on motor) |
| Connector (Motor End) | M23 23-pin (motor-side mating connector) |
| Brake Wire | 2× 0.75mm² included |
| EMC Compliance | CE, UL Listed |
Functional Features:
- Pre-terminated at factory — eliminates field wiring errors.
- Double shielding provides superior noise immunity in high-EMI environments.
- PUR jacket resists cutting oils, coolants, and mechanical abrasion.
- Brake wire integrated for motors with holding brakes.
- Strain relief at both connector ends to prevent cable pull-out.
Structural Features:
- 5-core power cables (U, V, W, PE, PE) plus 2 brake wires.
- M23 circular connectors with IP67 rating when mated.
- Cable bend radius: minimum 6× cable diameter.
Applicable Industries:
- CNC machining centers
- Robotics
- Injection molding machines
- Metalworking equipment
- Any Kollmorgen servo motor installation
Installation Requirements:
- Route cable away from high-current power lines (minimum 100mm separation).
- Use cable clamps every 500mm for fixed routing.
- Do not exceed minimum bend radius of 6× OD (approx. 70mm).
- Verify connector pin alignment before mating — do not force.
Usage Precautions:
- Do not cut or modify the cable — use the complete assembly only.
- If cable length is insufficient, order a new assembly — do not splice.
- Replace immediately if outer jacket shows cuts, cracks, or chemical damage.
- Store in a dry environment; avoid UV exposure for extended periods.