Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen CE06260
Detailed content
Technical Specifications:
-
Input Voltage: 110–230 VAC, 1-phase or 3-phase, 47–63 Hz
-
Continuous Output Current: 10 A (7.8 A RMS minimum depending on supply)
-
DC Bus Range: 90 VDC undervoltage threshold, 430 VDC overvoltage clamp
-
Power Rating: 0.7/1.1 kVA (1φ/3φ) at 115 VAC; 1.4/2.2 kVA at 230 VAC
-
PWM Switching Frequency: 8 kHz
-
Protection: External bleed resistor support, bus over/undervoltage monitoring
-
Cooling: Natural convection
-
Mounting: DIN/panel module, screw terminals
Features: Auto motor recognition with compatible Kollmorgen drives, integral current/voltage modulation, compact book-style housing.
Applications: Retrofit machine tools, packaging axes, material handling, general servo retrofits.
Installation Notes: Requires 230 VAC class grounding, leave 50 mm side clearance for convection, torque terminals to 1.2 Nm.
Precautions: Never connect 400 VAC mains directly; bus capacitance must be discharged before service.