Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen CE06200-00000012
Detailed content
Technical Specifications:
-
Input Voltage: 115/230 VAC single or three-phase
-
Continuous Output Current: 6 A RMS
-
Peak Output Current: 18 A for 500 ms, 12 A for 2 s
-
Output Power: 0.7 kVA (115 V 1φ) to 2.2 kVA (230 V 3φ)
-
DC Bus Range: 90 VDC UV trip / 430 VDC OV trip
-
Heat Dissipation: ≈80 W
-
Ambient Temperature: 5 °C to 45 °C (derating above 45 °C)
-
Altitude: ≤1000 m without derating
-
Feedback: Sine encoder standard, resolver optional
Functional Features:
Same drive firmware architecture as CE10250 with scaled power stage; supports halt-on-fault, regenerative clamp via external resistor.
Application Scenarios:
Small Cartesian robots, medical motion stages, pick-and-place units, semiconductor handlers.
Use Precautions:
Not for use with 400 VAC mains unless external step-down transformer is applied. Do not share heat sink plane with 230 V drives without insulation.