Product Name: Servostar Series 2 Analog/Digital Servo Drive
-
Product Introduction: Legacy series drive (CD Servostar line) utilizing analog control interface primarily, designed for motor control with integrated incremental encoder feedback processing. Commonly found in refurbished/legacy system maintenance.
Detailed content
-
Technical Specifications:
-
Input Voltage: 110–230 VAC (single or three-phase)
-
Line Frequency: 47–63 Hz
-
Continuous Current: 10 A (single-phase) / 7.8 A (three-phase) for CE06200 (6 A rating nominal)
-
Peak Current: 30 A (500ms SP) / 20 A (2s SP) single-phase
-
Output Power: 0.89–2.8 kVA depending on input
-
Encoder Frequency: Up to 3 MHz (before quadrature x4)
-
Encoder Count: Up to 10 million counts per motor electrical cycle
-
Operating Temp: 5 °C to 45 °C (41–113 °F)
-
Protection: Undervoltage 90 VDC, Overvoltage 430 VDC
-
-
Functional Features:
-
Analog control interface with differential setpoint inputs.
-
Integrated incremental encoder with auto-configuration and index pulse offset.
-
PI current and speed controller with trimmer potentiometers.
-
24 V logic with optically isolated inputs (PLC compatible), relay output for system ready.
-
Ballast circuit with w-characteristic for energy dissipation, fuse protection on DC-link/aux supply.
-
-
Application Scenarios: Legacy industrial automation retrofits, older packaging lines, textile machinery, lab equipment using analog servo control.
-
Structural & Material Characteristics: Eurocard style PCB (approx. 199×100 mm or double Eurocard 220×233.4 mm for larger units), SMD technology, DIN 41612connectors, LED diagnostic indicators, IP 00 (requires cabinet).
-
Working Principle: Analog/digital hybrid PI control loops regulate 4-quadrant V-MOS transistor output stage; motor position tracked via incremental encoder interface; tachometer or armature voltage control optional via solder links.
-
Installation Requirements: Install in closed switchgear cabinet; natural convection cooling for <8A continuous, forced convection above; keep away from corrosive gases/dust; 24 VDC aux supply optional.
-
Usage Precautions: Altitude derating 5% per 300m above 1000m; humidity 5–85% non-condensing; ensure proper fusing (15 A line fuse typical); thermal monitoring active but cabinet ventilation mandatory; obsolete series, spares limited.