Kollmorgen CB10560
Product Series: Kollmorgen SERVOSTAR CD Family — 230 VAC Class
Product Brief: Compact digital brushless servo drive for 3-phase PMSM/BLDC motors. CD10560 variant provides 5 A continuous / 10 A peak output from 208–230 VAC 3Φ input. Features SERCOS interface option or analog ±10 V / step-dir control depending on interface card fitted. CB10560 in OEM lists typically references the CD10560 drive itself (catalog cross-reference: CB = Configured Build of CD platform).
Detailed content
Input Supply Voltage (Power): 208 – 230 VAC 3Φ, 50/60 Hz
DC Bus (Nominal): ≈ 325 VDC
Continuous Output Current (RMS): 5.0 A
Peak Output Current (RMS, 0.5 s): 10.0 A
Control Logic Supply: +24 V DC (18–30 VDC), isolated
Communication / Control Interface: SERCOS (optical fiber) standard on CD-c; analog ±10 V + step/dir + encoder follower available on selected I/O cards
Supported Feedback: Resolver (std), Incremental Encoder (TTL/RS-422), SinCos 1 Vpp (option-dependent)
PWM Switching Frequency: 8 kHz / 16 kHz (programmable)
Protections: Overcurrent, bus UV/OV (UV ≈ 90 VDC, OV ≈ 430 VDC), I²t motor overload, phase-phase & phase-ground short, heatsink OT
Dimensions (H × W × D): 244 mm × 75 mm × 163 mm (typical CD narrow-width variant) or 100 mm W for full CD — verify nameplate
Weight: ≈ 2.0 kg
Cooling: Natural convection (ventilated cabinet) or forced air
Protection Class: IP20
Operating Temperature: 0 °C to +45 °C (full); derating to +55 °C
Certifications: CE, UL, cULus
Applicable Industries: Small-to-medium packaging machines, labeling heads, electronic component inserters, textile winders — legacy SERCOS-based systems
Installation Requirements: Vertical panel mount in grounded enclosure; 3Φ 230 VAC via line filter + contactor; PE bond; SERCOS fiber connection with proper ring termination; verify node address DIP switches.
Usage Notes: Legacy product — replaced by AKD/AKD2G; verify actual current rating on nameplate (CD10560 = 5 A cont; CD10661 = 6 A or 13 A); external regen resistor may be needed; if unit is actually a cable (rare CB10560 cable ref), treat per cable installation rules — separate power/feedback, shield grounded at drive end only.