- KOLLMORGEN BE2-090-14
Detailed content
Key Specifications:
- Model Code Breakdown:
- BE2 = Brake Energy Resistor, Series 2
- 090 = 90 Ω resistance value
- 14 = 1400 W power rating (continuous)
- Resistance Value: 90 Ω (±5% tolerance)
- Continuous Power Rating: 1400 W (at 25°C ambient, natural convection)
- Peak Power Rating: 2800 W (10-second duration, 1 cycle per minute)
- Max Voltage: 600 VDC (do not exceed — insulation breakdown risk)
- Thermal Capacity: High thermal mass ceramic-wirewound construction
- Protection Rating: IP00 (open frame, requires enclosure mounting)
- Cooling: Natural air convection (no fan)
Structural Features:
- Construction: Ceramic substrate with nickel-chromium resistance wire, aluminum housing
- Dimensions (approx.): 180 mm × 120 mm × 80 mm (W×H×D)
- Weight: Approximately 3.5 kg
- Mounting: Panel mount with M6 bolt holes (4-point mounting)
- Terminals: Screw terminals (M6, accepts up to 10 mm² cable)
Electrical Parameters:
| Parameter | Value |
|---|---|
| Resistance | 90 Ω (±5%) |
| Continuous Power | 1400 W |
| Peak Power | 2800 W (10 s) |
| Max Voltage | 600 VDC |
| Inductance | < 5 µH |
| Operating Temperature | -25°C to +155°C (element temperature) |
| Compliance | CE, UL, cUL |
Working Principle:
During motor deceleration or braking, the servo drive switches to generator mode. The kinetic energy of the rotating load is converted to electrical energy and fed back into the DC bus. If the bus voltage exceeds the overvoltage threshold, the drive activates the brake chopper circuit, which routes excess energy to the external brake resistor. The resistor converts this electrical energy into heat, which is dissipated by natural convection.
Applicable Industries: CNC machines, cranes and hoists, elevators, conveyor systems (high-inertia loads), winding machines
Installation Requirements:
- Mount in well-ventilated enclosure — minimum 100 mm clearance on all sides
- Do not install near flammable materials
- Use 10 mm² minimum copper cable for connections
- Connect to drive brake output terminals (B1, B2) — observe polarity
Usage Notes:
- Derate power by 1.5% per °C above 25°C ambient
- Do not operate above 600 VDC — will cause insulation failure and fire hazard
- Ensure enclosure has adequate ventilation or forced air cooling for continuous operation