Digital guide

You are here:

Kollmorgen B-404S-C-93-B3-072

Product Brief:​ B-404S indicates frame 40, S = special stack variant; “-C-” = C-winding (higher torque constant than B-winding, lower max speed — typical continuous stall torque for B-404C ~5.5–6.5 Nm). “93” = keyed shaft + standard seals; “B3” = circular connector + shaft seal; “-072” = special lamination stack length 72 mm​ (non-standard — standard stacks are typically ~50/65/80 mm for B-40x; 072 is a custom length altering inertia and torque proportionally). Factory-fitted with 2-pole resolver. Compatible with SERVOSTAR S300/S600/S700 and AKD (120/240 V models for C-winding).

Detailed content

Frame Size:B-40x — Flange 110 mm × 110 mm, shaft Ø 19 mm​ with keyway
Stack Length (Special):72 mm​ (custom — alters Tc and J per proportionality to standard stack)
Estimated Continuous Stall Torque (Tc, C-wdg, 72 mm stack):≈ 6.0 – 7.0 Nm​ (proportional to standard B-404C ~5.8 Nm @ std stack × ratio)
Peak Torque (Tp):≈ 18 – 21 Nm
Rated Speed (nN, C-winding):3000 rpm​ (C-winding typically limited to 3000 rpm @ 230 VAC)
Rated Power (Continuous):≈ 1.9 – 2.2 kW
Rated Current (RMS):≈ 5.0 – 6.0 A
Peak Current (RMS):≈ 15 – 18 A
Torque Constant (Kt, line-line):≈ 1.20 – 1.35 Nm/A
Back-EMF Constant (Ke, line-line):≈ 80–90 V/krpm (RMS)
Winding Resistance (Line-Line, 25 °C):≈ 0.8 – 1.2 Ω
Winding Inductance (Line-Line):≈ 6 – 10 mH
Rotor Inertia (without brake, 72 mm stack):≈ 1.1 – 1.3 × 10⁻⁴ kg·m² (1.1–1.3 kg·cm²)​ (proportional to stack length)
Brake:​ None (unless -Bxx option present — not shown)
Feedback Device:2-pole Resolver (standard Goldline B)
Insulation Class:Class F (155 °C)
Protection Class:IP65​ (shaft seal + O-ring on connector)
Cooling:​ Natural convection
Operating Temperature (Ambient):0 °C to +40 °C rated; –20 °C to +55 °C with derating
Connector Type:​ Circular M23 / Intercontec (power + feedback)
Weight (approx., 72 mm stack):≈ 6.0 – 7.0 kg
Compliance:​ cURus, CE (per base Goldline B certification)
Applicable Industries:​ Custom converting winders requiring intermediate torque between std B-404C and B-406C, special-machine textile take-ups, paper converting custom builds
Installation Requirements:​ Same as B-404 standard — 110 mm flange mount; verify coupling fits extended length due to special stack; connect PE; shielded feedback cable.
Usage Notes:​ This is a custom/modified standard​ — exact torque/current values should be taken from the individual motor nameplate, not generic catalog curves; Goldline B discontinued — consult Kollmorgen for AKM equivalent sizing; resolver auto-commutated by AKD/S700.

You may also like