Digital guide

You are here:

Kollmorgen AKM54H-ACCNR-00

Product Introduction:​ High-torque-density, low-cogging brushless servo motor from Kollmorgen AKM family. Designed for plug-and-play with S700/AKD drives via electronic nameplate auto-configuration. “ACCNR” decode: A=Standard flange(IEC72-1), C=Winding code H (medium speed/high torque), C=Resolver feedback, N=No holding brake, R=Keyway shaft, 00=Standard options.

Detailed content

  • Performance Parameters (typical, Winding H, 400 V AC / 320–640 V DC bus):
    • Stall Torque (T₀):​ 14.19 N·m
    • Stall Current (I₀):​ 5.50 A RMS
    • Peak Torque (T_pk):​ 37.5 N·m (short duration)
    • Peak Current:​ 16.5 A RMS
    • Rated Speed (max mechanical):​ 6000 rpm
    • Rated Power (at 3000 rpm / 560 V bus):​ approx. 3.0–4.4 kW depending on load point
    • Torque Constant (K_t):​ ~2.58 N·m/A
    • Back-EMF Constant (K_e):​ ~155 Vpeak/krpm (or ~97 Vrms/krpm)
    • Rotor Inertia (J_m):​ 11.9 × 10⁻⁴ kg·m² (11.9 kg·cm²)
    • Winding Resistance (line-to-line):​ ~2.25 Ω (typical for H-winding)
    • Inductance (L-L):​ ~22 mH (typical)
    • Number of Pole Pairs:​ 5 (10 poles)
  • Mechanical:
    • Frame Size:​ AKM54 — Flange 108 × 108 mm, Bolt Circle ⌀130 mm, Pilot ⌀110 mm
    • Shaft:​ ⌀24 mm with keyway (DIN 6885), shaft length ~50 mm
    • Motor Length (w/o connector):​ approx. 198 mm (body) / overall ~221 mm
    • Holding Brake:​ None (“N” in code)
    • Feedback:​ 2-pole resolver (accuracy ±8 arc-min), mounted inside rear cap
    • Connectors:​ 2 × M23 angular SpeedTec Ready connectors (power + feedback), rotatable 4×90°
    • Thermal Sensor:​ PTC thermistor (KTY84 or equivalent) in winding
    • Mass:​ approx. 9.0 kg
  • Protection:​ Standard IP54 (shaft seal option upgrades to IP65), Insulation Class F/H (155 °C / 180 °C)
  • Mounting:​ Flange mount, IM B5 (face mount). Tapped holes in flange for through-bolts or foot mounts optional.
  • Application Areas:​ Packaging machines, printing presses, CNC rotary axes, material handling, robotics requiring high continuous torque.
  • Installation Notes:​ Align coupling to avoid radial load on shaft bearings. Connect shield of power cable to PE terminal in drive. Verify motor phase order (U-V-W) if manual connection; resolver wired per pinout. Allow free convection — leave ≥50 mm clearance at non-drive end.