Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen AKM54H-ACCNR-00
Kollmorgen AKM54H-ACCNR-00
Product Introduction: High-torque-density, low-cogging brushless servo motor from Kollmorgen AKM family. Designed for plug-and-play with S700/AKD drives via electronic nameplate auto-configuration. “ACCNR” decode: A=Standard flange(IEC72-1), C=Winding code H (medium speed/high torque), C=Resolver feedback, N=No holding brake, R=Keyway shaft, 00=Standard options.
Detailed content
-
Performance Parameters (typical, Winding H, 400 V AC / 320–640 V DC bus):
-
Stall Torque (T₀): 14.19 N·m
-
Stall Current (I₀): 5.50 A RMS
-
Peak Torque (T_pk): 37.5 N·m (short duration)
-
Peak Current: 16.5 A RMS
-
Rated Speed (max mechanical): 6000 rpm
-
Rated Power (at 3000 rpm / 560 V bus): approx. 3.0–4.4 kW depending on load point
-
Torque Constant (K_t): ~2.58 N·m/A
-
Back-EMF Constant (K_e): ~155 Vpeak/krpm (or ~97 Vrms/krpm)
-
Rotor Inertia (J_m): 11.9 × 10⁻⁴ kg·m² (11.9 kg·cm²)
-
Winding Resistance (line-to-line): ~2.25 Ω (typical for H-winding)
-
Inductance (L-L): ~22 mH (typical)
-
Number of Pole Pairs: 5 (10 poles)
-
-
Mechanical:
-
Frame Size: AKM54 — Flange 108 × 108 mm, Bolt Circle ⌀130 mm, Pilot ⌀110 mm
-
Shaft: ⌀24 mm with keyway (DIN 6885), shaft length ~50 mm
-
Motor Length (w/o connector): approx. 198 mm (body) / overall ~221 mm
-
Holding Brake: None (“N” in code)
-
Feedback: 2-pole resolver (accuracy ±8 arc-min), mounted inside rear cap
-
Connectors: 2 × M23 angular SpeedTec Ready connectors (power + feedback), rotatable 4×90°
-
Thermal Sensor: PTC thermistor (KTY84 or equivalent) in winding
-
Mass: approx. 9.0 kg
-
-
Protection: Standard IP54 (shaft seal option upgrades to IP65), Insulation Class F/H (155 °C / 180 °C)
-
Mounting: Flange mount, IM B5 (face mount). Tapped holes in flange for through-bolts or foot mounts optional.
-
Application Areas: Packaging machines, printing presses, CNC rotary axes, material handling, robotics requiring high continuous torque.
-
Installation Notes: Align coupling to avoid radial load on shaft bearings. Connect shield of power cable to PE terminal in drive. Verify motor phase order (U-V-W) if manual connection; resolver wired per pinout. Allow free convection — leave ≥50 mm clearance at non-drive end.






.jpg)