Kollmorgen AKM52K-SSS2S-06
-
Product Name: AKM™ Series AC Synchronous Servo Motor, Frame Size AKM52 (Flange 115 mm / 130 mm OD), Stack Length K (long), 480 V AC winding, resolver feedback, smooth shaft, no brake, M23 connector
-
Product Introduction: The AKM52 is a high-power-density permanent-magnet AC servo motor from Kollmorgen’s AKM family. The “K” stack length gives the highest continuous torque in the AKM5 frame. “SSS2S-06” decodes approximately to: Standard (S) flange/IEC tolerance, Smooth shaft (S), Single resolver feedback (S), 2 = standard seal, S = no brake, -06 = 480 V winding / specific connector orientation.
Detailed content
-
Typical Performance Parameters (AKM52K — 480 V winding):
-
Continuous (Stall) Torque (Tc): ≈ 8.6 N·m (76 lb-in)
-
Peak Torque (Tp): ≈ 24–27 N·m (depending on exact winding)
-
Rated Speed: 3000 RPM (typical for 480 V winding)
-
Max Speed: up to 4500–5000 RPM (depending on feedback and balancing)
-
Continuous Current (Ic): ≈ 7.5–9.0 A RMS (at 100 °C ΔT)
-
Peak Current (Ip): ≈ 21–25 A RMS (short duration)
-
Torque Constant (Kt): ≈ 1.1–1.2 N·m/A RMS
-
Back EMF Constant (Ke): ≈ 70–80 V/kRPM (line-line RMS)
-
Rotor Inertia: ≈ 0.011–0.013 kg·m²
-
Winding Voltage: 480 V AC (suitable for 320–640 V DC bus)
-
Feedback Device: Brushless resolver (standard on S-code)
-
Brake: None (S = no brake)
-
Shaft: Smooth (no keyway), diameter typically 22 mm or 24 mm (check drawing)
-
Connector: 2 × M23 (power + feedback), angled or straight per option
-
Ingress Protection: IP65 with shaft seal; IP54 without
-
Insulation Class: F (155 °C), windings rated at 100 °C temp rise over 40 °C ambient
-
Ambient Temp. Range: 0 … +40 °C (–20 °C storage)
-
Compliance: cURus, CE, RoHS
-
-
Features: Low cogging due to skewed magnets; optimized slot/pole combination; global voltage compatibility; direct mate to AKD / S700 / S600 series drives.
-
Applications: CNC machine tool axis, large packaging/form-fill-seal machines, converting equipment, robotics joints, material test stands.
-
Installation Notes: Use Kollmorgen-specified motor power cable (shielded twisted pair + PE); tighten M23 connectors to specified torque (typically 0.8–1.2 N·m); align load coupling to avoid axial thrust on motor bearing.
-
Cautions: Do not exceed max radial/axial shaft load; verify resolver wiring polarity during first power-up; if brake were fitted, it would require 24 V DC — this unit has none.