Digital guide

You are here:

Kollmorgen AKI-CDT-MOD-10 T-000

Product Name: Kollmorgen AKI CANopen Distributed I/O Module — Terminal Side

Model Number: AKI-CDT-MOD-10 T-000

Product Category: Distributed I/O Module for CANopen Network

Series: AKI (AKD I/O Interface)

Detailed content

Communication Protocol: CANopen (DS301 compliant)

Module Position: Terminal Side (CDT = CANopen Distributed Terminal)

Module Number: MOD-10 (10 I/O points)

Configuration Code: T-000 (Standard Configuration)

I/O Points: 10 digital I/O points (configurable mix of inputs and outputs)

Digital Input Voltage: 24 VDC nominal

Digital Output Type: PNP transistor output, 24 VDC, 0.5 A per channel maximum

Input Filter: Configurable debounce time (typical 1–20 ms)

Communication Speed: 125 kbps to 1 Mbps (auto-baud)

Node ID: Set via DIP switches or software (range 1–127)

Power Supply: 24 VDC via bus power from AKD drive or external supply

Current Consumption: < 500 mA at 24 VDC (typical)

Protection Rating: IP20 (when mounted in enclosure)

Dimensions (approx.): 90 mm × 65 mm × 30 mm (W × H × D)

Mounting: DIN rail (35 mm) or panel mount

Material Composition:

  • Housing: Polycarbonate (UL94 V-0 rated)
  • Terminal blocks: Phosphor bronze, tin-plated
  • PCB: FR-4, conformal coated

Key Functional Features:

  • Terminal-side I/O extension for control cabinet wiring
  • Pairs with CDF (field-side) modules for complete distributed I/O architecture
  • Deterministic I/O update synchronized to servo axis cycle
  • Reduces point-to-point wiring from controller to field devices

Applicable Systems: Multi-axis servo systems using Kollmorgen AKD or AKD-P drives requiring terminal-side I/O expansion

Installation Requirements:

  • Mount on DIN rail inside control cabinet
  • Connect CAN_H and CAN_L to AKD drive CAN port
  • Connect 24 VDC power supply to terminal block
  • Configure node ID to avoid address conflicts on CAN bus