Digital guide

You are here:

Kollmorgen AKDI-P01206-NB CC-I0001

Product Introduction:​ Part of the AKD family of Ethernet-based servo amplifiers; the “P01206” segment denotes 120/240 VAC input, 12 A RMS continuous output, 4 kW continuous power. The “-NB” variant carries no base communication card (fieldbus card added separately); “CC-I0001” is an internal configuration/label suffix. Pairs natively with AKM brushless servo motors under plug-and-play auto-recognition via Kollmorgen WorkBench.

Detailed content

  • Technical Specifications:
    • Input Supply:​ 120/240 VAC single- or three-phase, 85–265 VAC operating range, 50/60 Hz
    • Control Power:​ 24 VDC logic
    • Continuous Output Current:​ 12 A RMS (±3%)
    • Peak Output Current:​ 30 A RMS for 5 s
    • Continuous Output Power:​ 4000 W
    • Current Loop Bandwidth:​ 2.5–4 kHz (digital, market-leading update rate ~0.67 µs)
    • Velocity Loop Bandwidth:​ 0–1000 Hz
    • Position Loop Update:​ 125 µs
    • Feedback Supported:​ SFD, EnDat 2.1/2.2, BiSS, analog sin/cos encoder, incremental encoder, HIPERFACE, resolver
    • Communication Options:​ EtherCAT, EtherNet/IP, PROFINET RT, Modbus/TCP, CANopen, SynqNet (via option card)
    • I/O:​ Optically isolated screw-terminal I/O, 8 digital in / 3 digital out (24 VDC), 1 analog in, 1 analog out
    • Protection:​ IP20, STO safety, over-current/over-voltage/over-temperature detection, SIL-capable
    • Operating Temp:​ 0 to +40 °C (derating above)
  • Functional Features:​ Fast commissioning with guided full-frequency autotuning, Bode plot optimization, TCP/IP service channel for real-time data capture, DSP-based vector control, electronic gearing, position/speed/torque modes, multi-axis sync via KAS.
  • Application Scenarios:​ Packaging machinery, printing presses, lab automation, medical devices, material handling, general single-axis servo retrofits.
  • Installation Requirements:​ Mount vertically in panel with minimum 50 mm top/bottom clearance for convection; secure to DIN rail or panel; separate 24 VDC control supply; shield motor and feedback cables, ground to PE bus.
  • Usage Notes:​ Do not power logic and mains from same unswitched source without sequencing; verify feedback card matches motor before enable; regen resistor built-in for NB variant only when specified—confirm braking energy budget.