Product Introduction:​ AKD drive variant for 240/480 VAC three-phase supply. The “T” in some legacy AKD coding can indicate a specific I/O or communications subset; “-NBA” typically = 480 V 3Ø input, analog ±10 V / pulse & direction command inputs, no built-in fieldbus master, standard I/O. Continuous rating follows AKD-x00307.

Detailed content

  • Performance Parameters:
    • Input Voltage: 187–528 VAC, 3-phase (240/480 VAC nominal)
    • Continuous Output Current: 3 Arms
    • Peak Output Current: 9 Arms (5 s)
    • Drive Continuous Output Power: ~2000 W
    • Current Loop Bandwidth: up to 2.5–4 kHz
  • Feedback / I/O:​ Same feedback device support as AKD family (SFD, EnDat, BiSS, resolver, encoders); analog command ±10 VDC torque/speed, step & direction; optically isolated I/O; 24 VDC logic supply
  • Structure:​ Approx. 168 × 57 × 153 mm (typical AKD small-frame); IP20; DIN-rail or panel mount; forced-air convection cooling
  • Features:​ Plug-and-play motor ID with AKM motors; auto-tuning; real-time performance monitoring; expandable via option cards (additional I/O, NVRAM)
  • Installation & Notes:​ Requires 3-phase supply; regenerative resistor may be needed; separate 24 VDC control supply; keep away from excessive vibration and conductive dust.