Digital guide

You are here:

Kollmorgen AKD-P04807-NB CC-E000

Product Introduction:​ The Kollmorgen AKD-P04807-NB is a three-phase, Ethernet-capable servo drive from the AKD platform, built for high-power single-axis motion control. The “P” denotes built-in position indexer firmware, “04807” indicates 48 A continuous output on a 240–480 VAC (07) supply, “NB” means no base communication card (analog ±10 V command, optically isolated I/O), and “CC-E000” is the plain I/O configuration without option cards. It pairs natively with AKM and legacy Kollmorgen motors through Kollmorgen WorkBench.

Detailed content

Technical Specifications:
  • Input Voltage:​ 3 × 187–528 VAC (rated 240–480 VAC)
  • Control Supply:​ 24 VDC ±10%
  • Continuous Output Current:​ 48 A RMS
  • Peak Output Current:​ 96 A RMS for 5 s
  • Continuous Output Power:​ 32,000 W (32 kW)
  • DC Bus Range:​ 340–680 VDC
  • Current Loop Bandwidth:​ up to 2.5–4 kHz
  • Velocity Loop Bandwidth:​ up to 1000 Hz
  • Position Loop Bandwidth:​ 1–250 Hz
  • Feedback Support:​ SFD, EnDat 2.1/2.2, BiSS, HIPERFACE, resolver, incremental/sine-cos encoder
  • I/O:​ Optically isolated screw-terminal digital I/O, analog in/out, CAN via RJ25, service Ethernet RJ45
  • Protection:​ IP20, STO (Safe Torque Off), over-voltage/current/temperature detection
  • Cooling:​ Forced convection, no fan on heat sink base
  • Dimensions (H×W×D):​ 248 × 96 × 228 mm (without connectors)
  • Weight:​ 3.7 kg
    Functional Features:​ Plug-and-play motor recognition, full-frequency wizard autotuning, 0.67 µs current-loop update, 125 µs position-loop update, real-time data acquisition over TCP/IP, BASIC/IEC 61131-3 motion tasks in indexer firmware.
    Application Scenarios:​ CNC axis drives, large packaging machinery, converting lines, press feeds, robotics joints requiring 10–30 kW sustained power.
    Installation Requirements:​ Mount vertically on panel with ≥50 mm top/bottom clearance; separate 24 VDC control supply from power ground; use Kollmorgen shielded motor and feedback cables; 3-phase supply requires proper PE bonding and line reactor if supply impedance is low.
    Usage Notes:​ Do not run at 48 A continuous without rated heatsink exposure; STO inputs must be wired before enabling; CC-E000 has no EtherCAT/Profinet onboard—add option card for fieldbus.