Product Introduction: The Kollmorgen AKD-P04807-NB is a three-phase, Ethernet-capable servo drive from the AKD platform, built for high-power single-axis motion control. The “P” denotes built-in position indexer firmware, “04807” indicates 48 A continuous output on a 240–480 VAC (07) supply, “NB” means no base communication card (analog ±10 V command, optically isolated I/O), and “CC-E000” is the plain I/O configuration without option cards. It pairs natively with AKM and legacy Kollmorgen motors through Kollmorgen WorkBench.
Detailed content
Technical Specifications:
-
Input Voltage: 3 × 187–528 VAC (rated 240–480 VAC)
-
Control Supply: 24 VDC ±10%
-
Continuous Output Current: 48 A RMS
-
Peak Output Current: 96 A RMS for 5 s
-
Continuous Output Power: 32,000 W (32 kW)
-
DC Bus Range: 340–680 VDC
-
Current Loop Bandwidth: up to 2.5–4 kHz
-
Velocity Loop Bandwidth: up to 1000 Hz
-
Position Loop Bandwidth: 1–250 Hz
-
Feedback Support: SFD, EnDat 2.1/2.2, BiSS, HIPERFACE, resolver, incremental/sine-cos encoder
-
I/O: Optically isolated screw-terminal digital I/O, analog in/out, CAN via RJ25, service Ethernet RJ45
-
Protection: IP20, STO (Safe Torque Off), over-voltage/current/temperature detection
-
Cooling: Forced convection, no fan on heat sink base
-
Dimensions (H×W×D): 248 × 96 × 228 mm (without connectors)
-
Weight: 3.7 kgFunctional Features: Plug-and-play motor recognition, full-frequency wizard autotuning, 0.67 µs current-loop update, 125 µs position-loop update, real-time data acquisition over TCP/IP, BASIC/IEC 61131-3 motion tasks in indexer firmware.Application Scenarios: CNC axis drives, large packaging machinery, converting lines, press feeds, robotics joints requiring 10–30 kW sustained power.Installation Requirements: Mount vertically on panel with ≥50 mm top/bottom clearance; separate 24 VDC control supply from power ground; use Kollmorgen shielded motor and feedback cables; 3-phase supply requires proper PE bonding and line reactor if supply impedance is low.Usage Notes: Do not run at 48 A continuous without rated heatsink exposure; STO inputs must be wired before enabling; CC-E000 has no EtherCAT/Profinet onboard—add option card for fieldbus.