Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen AKD-P01207-NDE
Detailed content
Technical Specifications:
-
Input: 240/480 VAC 3-phase (187–528 VAC)
-
Continuous output: 12 A RMS
-
Peak output: 30 A RMS (5 s)
-
Continuous power: 8000 W
-
Logic: 24 VDC
-
Feedback: full AKD list incl. Hiperface DSL, SFD3
-
Fieldbus: EtherCAT (NDE = no option card needed, native EtherCAT)
-
Regen: none internal (N)
-
Width: extended 95 mm front / 100 mm rear
-
Dimensions: 256 × 95 × 185 mm
-
Weight: approx. 2.9 kg
-
Protection: IP20
Functional Features: Sub-100 µs EtherCAT cycle, 0.67 µs torque loop update, 27-bit feedback support, option slot for extra I/O or NVRAM, STO SIL3.
Application Scenarios: CNC spindle aux axes, multi-axis assembly platforms, semiconductor handlers, printing towers.
Installation Notes: Shared DC bus possible with AKD-P… mains modules; EtherCAT daisy-chain with shielded RJ45 or M12.
Usage Precautions: At 12 A continuous, forced cooling airflow ≥ 0.5 m/s across heatsink fins required inside sealed cabinets.
.jpg)