Digital guide

You are here:

Kollmorgen AKD-P01207-NBE

Product Name: Kollmorgen AKD-P01207-NBE — Servo Drive (AKD-P Series)

Product Introduction: The AKD-P01207-NBE is a servo drive from Kollmorgen’s AKD-P programmable series, configured for EtherNet/IP communication with enhanced networking capabilities.

Model Series: AKD-P (Advanced Kinetics Drive — Programmable)

Detailed content

Product Category: Multi-Axis Servo Drive (Single-Axis Module)

Key Specifications:

Parameter Value
Continuous Current per Axis 7.0 A RMS
Peak Current per Axis 21.0 A (3× rated)
DC Bus Voltage 24–60 V DC (nominal 48V)
Number of Axes 1 (single-axis module)
Control Modes Position, Velocity, Torque, Cyclic Synchronous
Feedback Support EnDat 2.2, Hiperface DSL, BiSS-C, SSI, Incremental
Primary Communication EtherNet/IP (CIP Motion)
Secondary Communication EtherCAT, PROFINET, CANopen, Modbus
PWM Frequency 16 kHz (configurable to 32 kHz)
Digital I/O 16 inputs / 8 outputs
Analog I/O 2 inputs / 2 outputs
Safety Functions STO, SS1, SLS, SLP, SOS (SIL3 / PL e)
Operating Temperature 0°C to +50°C
Dimensions (W×H×D) ~48 × 120 × 110 mm
Weight ~0.55 kg
Certifications CE, UL, cUL, TÜV, RoHS
Part Suffix NBE = Network + EtherNet/IP + Enhanced

Functional Features:

  • EtherNet/IP native — seamless integration with Allen-Bradley / Rockwell platforms
  • CIP Motion profile — Vendor-specific for RSLogix / Studio 5000
  • Built-in web server with real-time status dashboards
  • Electronic gearing ratio up to 1:10000
  • Adaptive feedforward for load disturbance rejection

Working Principle: Identical to AKD-P02406-NCP with EtherNet/IP as primary fieldbus. CIP Motion commands traverse the network to the drive’s motion engine. Encoder feedback closes all servo loops internally.

Advantages:

  • Native Rockwell integration — no gateway required
  • 7A continuous rating — handles medium-to-heavy loads
  • Full safety suite — SIL3 certified without external components
  • Dual-protocol — EtherNet/IP primary, EtherCAT secondary for expansion

Applicable Industries:

  • Rockwell-based automation lines
  • Automotive body shops
  • Heavy packaging machinery
  • Print and convert equipment
  • Material handling systems

Installation Requirements:

  • DIN rail 35mm mounting
  • EtherNet/IP cable: shielded CAT5e/CAT6, max 100m per segment
  • Configure drive IP address via boot-up web page or AKD Workbench
  • Separate power and signal grounding

Usage Notes:

  • Set CIP Motion instance in RSLogix 5000 before commissioning
  • Use 120Ω termination resistor at each end of EtherNet/IP daisy chain
  • Perform auto-tune after any mechanical coupling change