Kollmorgen AKD-P01207-NBC
Product Name: AKD Series Servo Drive, Position Indexer Version, 12 A, 240/480 V AC
Product Introduction: “P” = Position indexer (built-in motion task execution), “012” = 12 A continuous, “07” = 240/480 V input, “NBC” = No brake resistor, B? (often B = Basic/Indexer already covered by P, C = certain feedback/connector config — resolver/encoder options), “N-0081” is likely a firmware/revision or custom spec identifier.
Detailed content
Technical Specifications:
-
Input: 240/480 V AC 3-phase (187–528 V)
-
Continuous Current: 12 A RMS
-
Peak Current: 36 A RMS
-
Power: ~8000 W continuous
-
Control: Built-in indexer (motion programs, electronic cam/gear)
-
Feedback: Sine/Cos, resolver, EnDat, BiSS, Hiperface, SFD (NBC typically resolver/standard encoder)
-
I/O: 8 digital in, 3 digital out, 1 analog in/out (16-bit)
-
Communication: EtherCAT/CANopen capable (depending on installed option)
-
Protection: IP20, optional STO
-
Operating Temp: 0–40°C (to 55°C derated)
Functional Features:
-
Standalone motion: Execute complex profiles without external controller.
-
AKD WorkBench: PC software for tuning, plotting, programming.
-
Dual-port EtherCAT: For daisy-chain networking.
-
Removable screw terminals: Power, brake, I/O.
Material & Structure:
-
Enclosure: Rigid metal with side vents, DIN/panel mount.
-
Electronics: High-speed DSP + FPGA, regenerative bus management.
Working Principle:
Host or internal indexer generates trajectory; drive closes position/speed/current loops, outputs PWM to motor; feedback processed on-board for commutation and correction.
Application Scenarios:
Multi-axis machines with distributed intelligence, labeling machines, electronic assembly, medical device manufacturing, printing where each axis runs local routines.
Installation Requirements:
-
Secure earth ground (PE) connection mandatory.
-
If regenerative energy high, add external brake resistor (NBC = no internal).
-
Allow ~100 mm top/bottom clearance for convection.
Usage Precautions:
-
Firmware “N-0081” may dictate feature set — verify compatibility with AKD WorkBench version.
-
Indexer programs reside in volatile/non-volatile memory — backup regularly.
-
Observe STO wiring if safety integrity required.





.jpg)