Product Series:​ Kollmorgen AKD™​ Family — 240/480 VAC 3-Phase Variant (“-xzzz07”)
Product Brief:​ High-performance single-axis servo amplifier for PMSM, asynchronous AC, linear, and DC brush motors. “P01207” = P-version (187–528 VAC 3Φ input), 12 Arms continuous / 30 A peak. “N” = no extra option card fitted (fieldbus slot empty). “B” = No built-in fieldbus interface card — analog ±10 V, Step/Dir, Encoder Follower, and Modbus TCP via Ethernet port are standard. Final “—” (no trailing letters) = Standard I/O, no STO. Fully auto-recognizes AKM/AKM2G motors via M23 connector ID resistors.

Detailed content

Input Supply Voltage:187 – 528 VAC 3Φ​ (nominal 240/400/480 VAC), 50/60 Hz
DC Bus Voltage (Nominal):~340 VDC @ 240 VAC in, ~565 VDC @ 400 VAC in, ~680 VDC @ 480 VAC in
Continuous Output Current (RMS):12.0 A
Peak Output Current (RMS, 5 s):30.0 A
Drive Continuous Output Power (Typical):8000 W​ @ 400 VAC
Control Logic Supply:+24 V DC​ (18–30 VDC), isolated, typ. 0.5 A (no brake); 1.5 A (with brake)
Torque Loop Update:0.67 µs
Velocity Loop Update:62.5 µs
Position Loop Update:125 µs
Current Loop Bandwidth:​ Up to 2–4 kHz
Supported Feedback Types:​ Resolver, SFD/SFD3, EnDat 2.1/2.2, BiSS-C, HIPERFACE/HIPERFACE DSL, SinCos 1 Vpp, Incremental TTL (A/B/Z up to 5 MHz), Tamagawa Smart Abs
Communication:​ Ethernet (10/100Base-T) for Modbus TCP, KAS-SoftMotion (if licensed), WorkBench commissioning; no EtherCAT/Profinet/Powerlink card fitted
Digital I/O:​ 7× DI (24 V opto-isolated, programmable), 3× DO (24 V 100 mA open-collector), 1× relay output (30 VDC / 1 A)
Analog I/O:​ ±10 V differential command input, ±10 V analog monitor output
Regenerative Chopper:​ Integrated (external brake resistor recommended for high-inertia deceleration)
Dimensions (H × W × D):196 mm × 78 mm × 187 mm
Weight:≈ 2.1 kg
Protection Class:IP20
Operating Temperature:0 °C to +40 °C full rated; derating to +55 °C
Certifications:​ CE, UL, cULus, RoHS; SIL 2 achievable with STO option (this NB has no STO)
Applicable Industries:​ Packaging lines, converting winders, bottling carousels, printing press aux drives, textile take-up, general factory automation — wherever analog/step control or Modbus TCP suffices
Installation Requirements:​ Mount vertically in grounded enclosure with ≥ 50 mm top/bottom clearance; connect 3Φ supply via line filter + contactor sized ≥ 12 A cont / 30 A peak inrush; PE terminal ≥ 4 mm²; fit external regen resistor if regen > 10 % duty; set parameters before enabling.
Usage Notes:​ NB = no fieldbus card + std I/O + no STO — safety stop must be external if Cat 3/4 required; auto-tuning and motor ID same as all AKD drives via WorkBench; verify feedback matches drive port; Ethernet port for Modbus TCP and config only — not real-time motion bus.