Continuous Output Current: 12 A RMS
-
Peak Output Current: 30 A RMS (5 s)
-
Continuous Output Power: 4000 W
-
Logic: 24 VDC
-
Fieldbus: EtherCAT (NBC8 = EtherCAT CoE firmware/option)
-
Feedback: Full AKD list including SFD3, EnDat, BiSS, Hiperface DSL
-
Dimensions: 96/100 mm W, 248 mm H, 228 mm D
-
Weight: 3.7 kg
-
-
Functional Features: Real-time EtherCAT sync, distributed clock support, option cards for NVRAM/I/O expansion, SIL-capable protective functions.
-
Applications: Electronic camming, flying shear, multi-axis CNC, high-throughput packaging.
Cross-Compatibility Notes
-
CR06200, PRD-AM40ASIC-A2, BDS4A-230H-A27 are legacy SERVOSTAR CD / BDS4 generation — pair with Goldline B/M, DBL3, 6SM motors using resolver feedback.
-
AKD-B00306, AKD-P00606, AKD-P01206 and S70101 are modern digital drives — pair with AKM, AKM2G, DBL/DBK (via feedback card), and third-party motors with appropriate encoder/resolver interface.
-
AKM41H-ACCNC-00 is directly plug-and-play on AKD drives; on S700 use correct feedback evaluation; on CR06200/BDS4 require resolver-only commutation and external motor-data setup.
General Installation & Usage Warnings
-
Always mount drives in grounded metal enclosures with IP20 protection; respect specified clearances for convection.
-
Verify motor winding voltage matches drive DC bus / output voltage before energizing.
-
Use shielded motor cables with shield terminated at amplifier and motor end.
-
Enable STO wiring according to ISO 13849 / IEC 61800-5-2 when personnel safety is involved.
-
Do not mix 230 V motor windings with 480 V drive output without transformer or correct winding selection.
-
Legacy drives (SERVOSTAR CD, BDS4) require manual motor-parameter entry; AKD/S700 support auto-commissioning with Kollmorgen motors.