Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen AKD-P01206-NBC12
Kollmorgen AKD-P01206-NBC12
Product Introduction: 240 V variant of the AKD® platform. NBC12 decodes as 120/240 VAC (00306 power stage scaled to 01206 = 12 A), N = no internal regen resistor, B = CANopen, C = base option set, 12 = Kollmorgen configuration/variant code (extended I/O or firmware sub-revision). Supplies up to 4 kW continuous to AKM5/AKM4 motors.
Detailed content
-
Technical Specifications:
-
Supply voltage: 120–240 VAC 1φ or 3φ (85–265 VAC), DC bus 170–340 VDC
-
Control logic: 24 VDC
-
Continuous output current: 12 Arms
-
Peak output current: 30 Arms for 5 s
-
Continuous output power: 4000 W
-
Current loop bandwidth: 2–3 kHz
-
Velocity loop bandwidth: 0–600 Hz
-
Position loop bandwidth: 1–250 Hz
-
Internal regen resistor: None (external mandatory for regen)
-
Fieldbus: CANopen
-
Feedback: Full AKD suite (SFD, EnDat, BiSS, resolver, sin/cos, Hiperface)
-
I/O: Same AKD standard set; extended I/O per “12” config
-
Protection: IP20
-
Dimensions: 248 mm H × 96 mm W × 228 mm D (without connectors)
-
Weight: 3.7 kg
-
-
Functional Features: CANopen DSP-402 profile, PLCopen motion, onboard indexer, same autotune/workbench ecosystem as all AKD units.
-
Application Scenarios: CANopen machine networks, cartoners, fillers, converting lines, rotary tables using Kollmorgen AKM51E or AKM42G at 240 V.
-
Material & Structure: Identical AKD mechanical platform; taller 240 V 12 A heatsink; CANopen connector on front option bay.
-
Working Principle: Same FOC inversion as other AKD; CANopen master sends target via PDO/SDO.
-
Mounting Requirements: Panel mount vertical, enclosed; because no internal resistor, an external Kollmorgen regen resistor must be fitted when decelerating inertial loads downward.
-
Usage Notes: Do not run 480 V supply into this unit. Brake circuit (if motor has 24 V brake) must be externally wired. CAN bus termination 120 Ω at both ends.







.jpg)