Technical Specifications:
-
Model Breakdown: P = PANEL/book style, 003 = 3 A cont., 07 = 240 VAC single/three-phase, N = no firmware option, B = base feedback (resolver/incr), A = analog/ptp, N = no safety, 0000 = standard
-
Continuous Current: 3 A RMS, Peak ~9 A
-
Supply: 120/240 VAC (7 = 240 V class)
-
Control Modes: Cyclic sync position/velocity/torque, CST, homing
-
Feedback: SFD, EnDat 2.2, BiSS, resolver, sin/cos
-
Communication: EtherCAT, CANopen, Profinet, Ethernet/IP via option cards
-
Safety: STO capable (option dependent)
-
-
Functional Features: Graphical AKD Workbench, 1 kHz update, auto motor ID, single-cable SFD-M support, regenerative resistor terminal.
-
Application Scenarios: New machine builds, retrofit of S400/SERVOSTAR CD, multi-axis centralized control.
-
Installation Notes: Book-style side-by-side mounting allowed with derating; use ferrite on motor cable if EMI appears; DC bus linkable for regen sharing.







.jpg)