Digital guide

You are here:

Kollmorgen AKD-P00306-NAE C-0051

  • Product Name:​ AKD Position Indexer Servo Drive, 3 A 240 VAC, No option card (N), Analog/Standard? (AE = base AKD with analog I/O and no fieldbus, or legacy code for “AKD Ethernet” base), C hardware revision, 0051 custom label
  • Product Introduction:​ Standard AKD-P 3 A drive, 240 VAC class, C-revision hardware (early STO-certified platform). Used as universal replacement for S400 3 A axes.

Detailed content

  • Technical Specifications:
    • Supply: 85–265 VAC 1/3-phase
    • Output: 3 A cont., 9 A peak, 1.1 kW
    • Logic: 24 VDC
    • Feedback: full AKD list
    • I/O: standard optically isolated set
    • Revision: C (STO certified, 1.3.x firmware lineage)
    • Tail C-0051: customer-specific label/software bundle
  • Functional Features:​ Same tuning/autotune as other AKD-P; supports Modbus/TCP native; STO SIL2.
  • Application Scenarios:​ OEM standard axis, 3 A motor drive, AKM53M-class motor.
  • Construction & Materials:​ Identical to AKD-P00306-NBCUS mechanically.
  • Installation Requirements:​ 24 VDC logic separate; ground bus bar; rotary connector torque.
  • Usage Notes:​ C-0051 is not a different hardware class; treat electrically as AKD-x00306; firmware must be ≥1.3 for STO compliance.
  • Cross-System Notes
    • Compatible Pairings:​ AKM53M-CNCNEM00 ↔ AKD-P00306-NAE / AKD-M00306-MCER (3 A drive matches ~11 Nm motor at 240 V). AKD-P00607-NAEC handles larger AKM6/7 or high-speed AKM5. S403BA-CA-022 pairs with R46GSNA or older AKM with resolver.
    • Cabling Rule:​ Use CR03251-class cables or current 2G cable guide; never mix encoder cable with resolver drive firmware.
    • Commissioning:​ AKD + AKM = auto-recognize feedback and motor electrics; S400 + AKM/R46 = manual motor table entry.
    • Safety:​ All AKD variants support STO (SIL2/PLe); S400 supports older enable/STO depending on option; brakes need external 24 VDC supervised supply.
    • Environment:​ AKM motors rated 0–40 °C ambient (derate 6 %/1000 m up to 1000 m+); AKD drives 0–40 °C, 95 % RH non-condensing; IP65 motor body, IP20 drive (panel).

You may also like