Digital guide

You are here:

KOLLMORGEN AKD-P003007-NB

Product Classification: Digital AC Servo Drive — AKD Series, 3 A Continuous, No Brake

Product Introduction:
The AKD-P003007-NB is a compact single-axis digital servo drive from the AKD family rated at 3 A continuous current with no brake output and standard communication configuration (no fieldbus — step/direction + analog). It is designed for cost-sensitive, single-axis applications where fieldbus communication is not required.

Detailed content

Technical Specifications:

Parameter Value
Drive Series AKD
Continuous Current Rating 3.0 A RMS
Peak Current Rating 9.0 A (3× continuous, 10-second)
Input Voltage 100–120 VAC (single-phase) or 200–240 VAC (three-phase)
Input Frequency 47–63 Hz
DC Bus Voltage 170 VDC (nominal)
Max Output Voltage 80 VAC (line-to-line)
Communication Protocol Step/Direction + Analog (no fieldbus)
Control Modes Position, Velocity, Torque
Position Loop Update Rate 125 µs (8 kHz)
Velocity Loop Update Rate 125 µs
Torque Loop Update Rate 62.5 µs (16 kHz)
Safety Functions STO (SIL2/PLc)
Brake Output No (NB = No Brake)
Digital I/O 4 inputs / 2 outputs (24 VDC)
Analog I/O 1 analog input (±10 V) / 1 analog output (±10 V)
Encoder Power Supply 5 VDC, 0.3 A
Protection Class IP20 (chassis mount)
Cooling Method Conduction (no fan — IC00)
Dimensions (W×H×D) 72 × 90 × 110 mm
Weight 0.85 kg
Ambient Temperature 0°C to +40°C
Certifications CE, UL, cUL

Functional Features:

  • Step/Direction interface — direct PLC or motion controller connection
  • Analog velocity/torque command — ±10 V input
  • Compact footprint — smallest AKD form factor (72 mm width)
  • STO safety — Safe Torque Off without external components
  • No fan design — silent operation, zero maintenance

Applicable Industries:

  • Simple axis positioning (conveyors, gates)
  • Laboratory equipment
  • Small CNC routers
  • Textile tension control
  • Fan/pump speed control

Model Series: AKD — Compact Digital Servo Drive Series (3 A class)

Installation Requirements:

  • Mount on DIN rail (TS35) or panel-mount with 2× M4 screws
  • Input power: 1.5 mm² minimum for 120 VAC
  • Step/Direction: differential line driver (RS-422) — max 10 m cable
  • Analog inputs: shielded twisted pair — max 5 m
  • Ground: PE ≥ 1.5 mm²

Usage Notes:

  • No fieldbus — all control via step/direction pulses + analog signals
  • Max pulse frequency: 500 kHz (position mode)
  • No brake output — external brake required for vertical loads
  • Derate current by 10% per 10°C above 40°C ambient