Digital guide

You are here:

Kollmorgen AKD-B02406-NCA

Product Family: AKD-B Series Basic Servo Drive

Product Overview:
The AKD-B02406-NCA is a single-axis servo drive from the AKD-B line. The “02406” denotes a 24A continuous current rating (12A RMS per phase). The “NCA” suffix indicates a North American variant with EtherCAT primary, CANopen secondary, and specific firmware/connector configuration.

Detailed content

Technical Specifications:

Parameter Value
Continuous Output Current 12 A RMS per phase (24A total system)
Peak Output Current 36 A (3x continuous)
Bus Voltage 48 VDC (nominal) / 80 VDC max
Supply Voltage Range 24–80 VDC
Feedback Types EnDat 2.2, Hiperface DSL, BiSS-C, Sincos/Cos, Hall
Communication EtherCAT (primary), CANopen, RS-232
Control Modes CSP, CSV, CST, Profile Velocity, Profile Position, Profile Torque, Homing
Motion Controller Basic (no onboard profile generator)
Axes 1 axis
Enclosure Rating IP20 (chassis mount)
Operating Temperature 0°C to +50°C
Weight (approx.) ~0.7 kg

Functional Features:

  • EtherCAT cyclic synchronization — 1 ms cycle time
  • CANopen DS402 profile support
  • Safe Torque Off (STO) — SIL 2 / PL c
  • Position following error limit and velocity window monitoring
  • Current control bandwidth: 1.6 kHz
  • Velocity control bandwidth: 400 Hz
  • Position control bandwidth: 200 Hz

Advantages:

  • High current capacity in a compact form factor
  • EtherCAT master/slave flexibility
  • No motion controller cost — offload to PLC or CNC
  • Suitable for high-inertia loads up to 24A continuous

Applicable Industries:
Heavy-duty conveyors, large CNC machines, injection molding, press machines, metal forming, woodworking centers

Series: AKD-B (Basic drive)

Installation Requirements:

  • DIN rail or panel mount with minimum 15 mm clearance (higher current = more heat)
  • Use 6 AWG power cables for 24A continuous current
  • Shielded EtherCAT cable (CAT5e or better)
  • Ground chassis to PE — do not float ground

Usage Notes:

  • Derate current by 10% per 10°C above 40°C ambient
  • For EtherCAT: configure PDO mapping for CSP mode (0x6040–0x6041)
  • Do not parallel outputs — each axis requires its own drive
  • Firmware updates via Kollmorgen Workbench — back up parameters first