Product Name:​ AKD Series Servo Drive, Basic Version (No Indexer), 6 A, 240/480 V AC
Product Introduction:​ A high-performance Ethernet-based servo drive from the AKD platform, offering fast loop updates and broad feedback support; “B” denotes Basic (no built-in motion indexer), “006” is 6 A continuous, “07” is 240/480 V input, “NBS” indicates no brake resistor, standard feedback options.

Detailed content

Technical Specifications:
  • Input Voltage:​ 240/480 V AC 3-phase (187–528 V AC)
  • Continuous Current:​ 6 A RMS
  • Peak Current:​ 18 A RMS
  • Continuous Output Power:​ ~4000 W
  • Control Modes:​ Torque, velocity, position (external controller)
  • Feedback:​ Sine/Cos encoder, resolver, Hiperface, EnDat, BiSS, SFD (depending on option)
  • Communication:​ Ethernet (modbus TCP), CANopen (optional), EtherCAT (optional — not in NBS base)
  • Protection:​ IP20, STO (Safe Torque Off) capable with option
  • Operating Temp:​ 0°C to +40°C (up to +55°C with derating)
  • Dimensions:​ Standard width ~65/70 mm (front/rear), height ~256 mm, depth ~185 mm
Functional Features:
  • Fast response:​ Current loop update ~1.5 µs, velocity ~62.5 µs, position ~125 µs.
  • Auto-tuning:​ Full auto and manual notch filtering.
  • Oscilloscope function:​ Built-in for commissioning.
  • Removable terminals:​ For power and I/O.
Material & Structure:
  • Housing:​ Aluminum/steel vented enclosure.
  • Internal:​ DSP/FPGA control architecture, integrated DC bus capacitors.
Working Principle:
Receives command from external motion controller via analog/PWM or bus, regulates three-phase output via space vector modulation, closing loops with high-resolution feedback.
Application Scenarios:
Retrofit systems, OEM machines with centralized motion control, robotics joints, converting equipment where drive is slave to PLC/CNC.
Installation Requirements:
  • Panel mount in grounded enclosure.
  • Maintain minimum spacing (typically 50 mm above/below) for airflow.
  • Use ferrite cores on motor leads if EMI issues arise.
Usage Precautions:
  • “NBS” means no internal brake resistor​ — external resistor required if regen energy exceeds bus capacity.
  • Verify voltage selector/jumper for 240 vs 480 V input region.
  • Ensure STO wiring if safety rated operation needed.