Digital guide

You are here:

Kollmorgen AKD-B00306-NCSA

Product Introduction:​ Part of Kollmorgen’s Ethernet-based AKD platform, this drive offers high bandwidth control and plug-and-play commissioning with AKM motors. The “B” denotes base indexer version, “00306” is 3A continuous at 120/240V, “NCSA” indicates no regenerative resistor, CANopen/SynqNet capable, standard firmware.

Detailed content

Technical Specifications & Performance Parameters:
  • Input Voltage:​ 85-265 VAC (120/240 VAC 1Ø/3Ø)
  • Continuous Current:​ 3 A rms
  • Peak Current:​ 9 A rms (5 sec)
  • Output Power:​ 1100 VA continuous
  • Current Loop Bandwidth:​ 2500-4000 Hz
  • Current Loop Update:​ 0.67 µs (~1.5 MHz)
  • Speed Loop Update:​ 62.5 µs (16 kHz)
  • Position Loop Update:​ 125-250 µs
  • Safety:​ STO (Safe Torque Off) included
Supported Feedback:​ SFD, SFD3, EnDat 2.1/2.2, BiSS, Hiperface DSL, Resolver, Incremental Sin/Cos, Comcoder
Communication:​ Analog ±10V, Pulse/Direction, SynqNet, CANopen, Modbus/TCP, EtherCAT (depending on option card)
Structure & Installation:
  • Dimensions:​ 57 mm (W) x 168 mm (H) x 153 mm (D)
  • Weight:​ ~1.1 kg
  • Connector Type:​ Detachable screw terminals, D-sub feedback ports
  • Cooling:​ Natural convection (no fan)
  • Protection:​ IP20
Functional Features:​ WorkBench GUI software, auto-tuning, dual loop support, electronic gearing, camming.
Applications:​ Lab automation, medical equipment, packaging, material handling.
Usage Notes:​ Requires 24VDC control supply. Ensure bus voltage does not exceed limits during decel. Use external brake resistor if regen energy exceeds internal capacity.