Digital guide

You are here:

Kollmorgen AKD-B00306-NBE

Product Introduction:​ The AKD-B series is a standard-performance single-axis servo drive from Kollmorgen’s AKD platform. It provides plug-and-play commissioning with Kollmorgen AKM servomotors and features Ethernet-based setup via Kollmorgen WorkBench software. The “B” denotes the base drive version without fieldbus; “N” = no options; “BE” typically indicates built-in EtherCAT option in some regional catalogs, but this unit is primarily analog/serial command capable.

Detailed content

  • Key Technical Specifications:
    • Supply Voltage:​ 85–265 VAC (120/240 VAC nominal), 1-phase or 3-phase, 50/60 Hz
    • Rated Continuous Output Current:​ 3 A RMS (±3%)
    • Peak Output Current:​ 9 A RMS (sustainable for 5 s)
    • Continuous Output Power:​ 1100 W @ 240 VAC
    • Control Logic Supply:​ 24 VDC
    • Current Loop Bandwidth:​ 2.5–4 kHz; Update Rate: 1.5 MHz (0.67 µs)
    • Velocity Loop Bandwidth:​ up to 1000 Hz
    • Position Loop Bandwidth:​ 1–250 Hz
    • PWM Switching Frequency:​ 10 kHz
    • Feedback Supported:​ EnDat 2.1/2.2, BiSS-C, HIPERFACE®, SFD (Smart Feedback Device), Sin/Cos encoder, Incremental encoder, Resolver
    • Digital I/O:​ 8 × 24 VDC inputs (sink/source), 3 × 24 VDC floating outputs
    • Analog I/O:​ 1 × ±10 VDC input (16-bit), 1 × ±10 VDC output (16-bit tachometer)
    • Safe Torque Off (STO):​ SIL2 / PL d compliant
    • Protection Class:​ IP20 (for cabinet mounting)
    • Operating Temperature:​ 0 to +40 °C (derate above 40 °C)
    • Dimensions (W×H×D):​ approx. 54 mm × 168 mm × 156 mm (without connectors)
    • Weight:​ approx. 1.1 kg
  • Structure & Material:​ Sheet-metal chassis with aluminum heat sink, screw-terminal power/I/O connectors, D-sub feedback connectors (X9/X10), RJ45/CAN bus ports.
  • Installation Requirements:​ Mount vertically inside a control cabinet with minimum 50 mm top/bottom clearance for convection cooling. Requires 24 VDC control supply and proper earth grounding. External regenerative resistor connectable via TB terminals.
  • Application:​ Semiconductor equipment, packaging machines, labeling systems, general-purpose single-axis positioning.
  • Notes:​ Do not exceed maximum DC bus voltage (~400 VDC). Use shielded motor/feedback cables. Auto-tuning recommended before first run.