Digital guide
You are here:
- Home
- Kollmorgen
- KOLLMORGEN 620-FAN
KOLLMORGEN 620-FAN
Product Classification: Accessory — Forced Air Cooling Fan for S600/S700 Series Servo Motors
Product Introduction:
The 620-FAN is a dedicated cooling fan assembly designed for mounting on Kollmorgen S600 and S700 series servo motors to provide forced-air convection cooling in applications where self-ventilation (IC411) is insufficient. It replaces or supplements the motor’s internal fan for high-duty-cycle or high-ambient-temperature operations.
Detailed content
Technical Specifications:
| Parameter | Value |
|---|---|
| Compatible Motor Series | S600, S700 |
| Compatible Frame Sizes | 60 mm, 72 mm, 80 mm |
| Fan Diameter | 62 mm (approx.) |
| Fan Thickness | 12 mm |
| Voltage Rating | 24 VDC |
| Current Draw | 0.15 A (max) |
| Airflow | 2.5 CFM (cubic feet per minute) |
| Static Pressure | 1.2 mmH₂O |
| Noise Level | < 42 dB(A) |
| Bearing Type | Sleeve bearing (long life) |
| Connector | 2-pin JST or bare leads |
| Operating Temperature | -20°C to +70°C |
| MTBF | > 50,000 hours |
| Weight | 28 g |
| Mounting Method | Snap-fit or screw-mount to motor end bell |
| Material | PBT plastic housing, aluminum impeller |
| IP Rating | IP20 |
Functional Features:
- Forced air cooling — increases continuous torque rating by 20–30%
- Low noise operation — sleeve bearing design
- Drop-in replacement for motor internal fan in high-load scenarios
- 24 VDC operation — compatible with standard drive auxiliary outputs
Applicable Industries:
- High-duty CNC spindle drives
- Continuous-run packaging machines
- Warm-climate installations (ambient > 40°C)
- High-torque low-speed applications
Model Series: 620 — Cooling Fan Accessory Series
Installation Requirements:
- Mount on motor non-drive end (NDE) end bell
- Ensure airflow path is unobstructed — minimum 10 mm clearance
- Wire to 24 VDC auxiliary output on servo drive
- Verify rotation direction — airflow must exit motor housing
Usage Notes:
- Do not operate fan without motor installed — unbalanced rotation causes vibration
- Clean fan blades quarterly in dusty environments
- Replace if noise increases > 5 dB above baseline (bearing wear indicator)







.jpg)