Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen 610-30 S61000-AC
Kollmorgen 610-30 S61000-AC
Product Name:
SERVOSTAR 610 Single-Axis Servo Drive
Product Introduction:
The S61000-AC is a 10 A continuous (20 A peak) drive in the S600 series, supporting 230–480 VAC input. “610-30” often refers to the 10 A rating with specific option coding. It includes built-in PLC-like functionality and broad feedback support.
Detailed content
Technical Specifications:
-
Input Voltage: 200–480 VAC 3-phase, 50/60 Hz
-
Continuous Output Current: 10 A RMS
-
Peak Output Current: 20 A RMS (5 s)
-
Supported Motor Power: ~7.5–11 kW (depending on voltage)
-
Control Modes: Position, velocity, torque
-
Position Accuracy: ±1 pulse (encoder-dependent)
-
Loop Update: Position 250 µs, Velocity 250 µs
-
Communication: RS232/485 std.; EtherCAT/CANopen/Profinet optional
-
Feedback: Incremental, absolute, SSI, resolver, Hiperface
-
Safety: STO, comprehensive fault protection
-
Protection: IP20 (std), optional IP54 front cover
-
Cooling: Forced convection (built-in fan for higher current units)
-
Weight: ~4 kg
Functional Characteristics:
-
Built-in motion task storage (up to 300 tasks)
-
Graphical debug via Kollmorgen Workbench
-
Multilingual interface
-
Compatible with AKM series motors
Application Scenarios:
-
Industrial robot joints
-
Semiconductor wafer transfer
-
CNC feed/spindle axes
-
High-speed packaging
Structural Features:
-
Book-size metal enclosure with side-mounted fan (S61000)
-
Front I/O with D-sub and screw terminals
-
Removable option cards for fieldbus
Working Principle:
Digital drive architecture with independent current (torque), velocity, and position loops; uses encoder/resolver feedback to close the loop and outputs SVM-based PWM to the motor phases, with optional onboard motion sequencing reducing PLC load.
Installation Requirements:
-
Fan intake/exhaust must remain unobstructed
-
Use external regenerative resistor for high-inertia deceleration
-
Proper fusing per UL/CE guidelines
Usage Precautions:
-
Peak current duration must not exceed 5 s continuously
-
Verify option card seating before power-up
-
STO circuits must be validated during machine acceptance