Product Name: 60WKS Series Analog Servo Amplifier
-
Product Introduction: Legacy compact high-performance analog brushless servo amplifier from the Seidel 60WKS line, designed primarily for Kollmorgen SM series brushless synchronous servo motors. Uses 4-quadrant output stage with ballast circuit.
Detailed content
-
Technical Specifications:
-
Supply Voltage: 3 x 60–172 VAC (50/60 Hz +/-10%)
-
Rated DC-Link Voltage: 240 V
-
Rated Output Current: 3 A (continuous 4Q operation)
-
Peak Output Current: 7.5 A (max ~5s)
-
Ballast Circuit Pulse Power: 5.4 kW
-
Ballast Continuous Power: 135 W
-
Minimum Motor Inductance: 5.0 mH
-
Weight: Approx. 1.4 kg
-
Protection: IP 00 (touch protection on power terminals)
-
Ambient Temp: 0–40 °C (derating 2.5%/°C up to 55 °C)
-
Aux Voltage: +/-15 V, 24 V DC (optional)
-
-
Functional Features:
-
4-quadrant V-MOS transistor output stage.
-
Integrated ballast circuit with w-characteristic for energy dissipation.
-
PI current and speed controller with trimmer adjustment.
-
Differential setpoint inputs, enable input, limit-switch inputs.
-
Monitoring for actual current, overvoltage, output stage temperature, short-circuit protection.
-
LED indicators for operational readiness/fault.
-
-
Application Scenarios: Retrofit of older SM-series motor systems, test rigs, semiconductor handlers, packaging machines using analog drives.
-
Structural & Material Characteristics: Double Eurocard format (220 x 233.4 x 45 mm), DIN 41612 C64/D32 backplane connectors, SubD 9-pin, Combicon screw terminals, natural convection cooling fins.
-
Working Principle: Analog PI regulators compare setpoint voltage with tacho/feedback signals to drive PWM generator controlling MOSFET bridge; DC-link energy managed by ballast resistor during deceleration.
-
Installation Requirements: Closed switchgear cabinet, vertical mount; natural convection requires uninterrupted airflow; max altitude 1000m; 24V aux supply if option fitted.
-
Usage Precautions: Obsolete/discontinued product; no modern bus communication; ensure minimum motor inductance 5.0 mH to prevent oscillation; ballast dissipation must be managed in cabinet thermal design; IP 00 requires touch-safe enclosure.