Digital guide
You are here:
- Home
- Kollmorgen
- Kollmorgen 1207-NBCC-0000
Kollmorgen 1207-NBCC-0000
Product Introduction:
This model is part of the AKD family, identified by “1207” as 7 A continuous at 480 VAC 3-phase input. The “NBCC” code defines network interface (EtherCAT/CANopen/Modbus TCP etc.), brake control, and connector style. It is a high-performance drive for single/multi-axis motion systems.
Detailed content
Technical Specifications:
-
Input Voltage: 380–480 VAC, 3-phase, 50/60 Hz
-
Continuous Output Current: 7 A RMS (some references cite 3.7 A for lower voltage variants; 1207 = 7 A @ 480 V)
-
Peak Output Current: ~14 A (2× continuous typical)
-
Output Power: ~1.5–2 kW
-
Control Modes: Torque, velocity, position
-
Communication: EtherCAT, CANopen, Modbus TCP/IP, Profinet IO, Ethernet/IP
-
Feedback Support: Resolver, incremental encoder, EnDat 2.2, BiSS, SFD, Hiperface
-
Safety: STO (Safe Torque Off), SS1 (Safe Stop 1) compliant with IEC 61800-5-2
-
Width: 40 mm (compact book-style)
-
Protection: IP20
Functional Characteristics:
-
High-bandwidth current loop (~2–4 kHz effective)
-
Graphical commissioning via Kollmorgen WorkBench
-
S-curve, trapezoidal, velocity contouring motion profiles
-
Autotuning and vibration suppression
Application Scenarios:
-
Electronics SMT pick-and-place
-
Lab automation
-
Multi-axis robotic cells
-
Converting and web-handling machinery
Structural Features:
-
Very narrow width for high-density cabinet layouts
-
Integrated I/O on removable terminal blocks
-
Status LEDs for drive health and E-stop/STO state
Working Principle:
Employs a 32-bit DSP/FPGA architecture to execute real-time torque/velocity/position loops, driving the motor via high-frequency PWM with dead-time compensation and field-oriented control (FOC).
Installation Requirements:
-
Requires 24 VDC auxiliary supply for control electronics
-
Maintain minimum spacing (typically ≥50 mm) above/below for airflow
-
Earth ground via PE terminal mandatory
Usage Precautions:
-
Do not remove connectors while powered
-
Verify STO wiring per machine safety category before enabling
.jpg)