Product Overview:
The 00D12B09101-5 is a Kollmorgen AKD servo drive, identified by its legacy part numbering system. This corresponds to a 7A continuous / 21A peak drive with 48 VDC bus, matching the AKD-P00607-NCA specification. The “00D12B09101” is the internal ordering code; “-5” indicates a specific firmware/configuration revision.
Key Technical Specifications:
| Parameter | Value |
|---|---|
| Continuous Output Current | 7 Arms (RMS) |
| Peak Output Current | 21 Arms (RMS) |
| DC Bus Voltage | 48 VDC (36–72 VDC range) |
| Continuous Power | ~340 W |
| Communication | EtherCAT, CANopen, USB, RS-232 |
| Control Modes | Current, Velocity, Position, CSP, CSV, CST |
| Feedback Support | Incremental encoder, SSI, BiSS, EnDat 2.2, Hiperface DSL, Resolver |
| Safety Rating | SIL 2 / PL d (STO, SS1, SOS, SLS, SLP, SBC) |
| Enclosure | IP20 (NEMA 1) |
| Operating Temperature | 0°C to +50°C |
| Dimensions | ~80 × 135 × 150 mm |
| Weight | ~0.85 kg |
| Certifications | CE, UL, cUL, RoHS, REACH, SIL 2, PL d |
Functional Features:
- Identical to AKD-P0°C to +80°C (flexing), -40°C to +105°C (static)** |
| Bend Radius (min) | 5× cable diameter (static), 10× cable diameter (dynamic) |
| Jacket Material | PUR (Polyurethane) |
| Color | Black (standard) |
| Weight | ~0.35 kg |
| Certifications | CE, UL, cUL, RoHS, REACH |
Functional Features:
- Heavy-gauge conductors — low voltage drop at high current
- Full shielding — prevents EMI coupling to encoder cables
- Gold-plated power contacts — low resistance, high reliability
- Strain relief — molded at both connectors
- 100% factory tested — hi-pot and continuity verified
Applicable Industries:
All Kollmorgen servo motor/drive applications requiring power connection
Installation Requirements:
- Route separately from encoder cables (min 100 mm separation)
- Ground shield at drive end only
- Use cable clamp within 150 mm of each connector
- Torque M23 connector locking nut to 1.0 Nm
Usage Notes:
- Do not exceed 10A continuous per conductor
- Replace if jacket is cut, crushed, or shielding is exposed
- Max recommended length: 10 m (beyond this, use larger gauge)