Digital guide

You are here:

Honeywell 51304465-300

Product Name:​ Shielded Twisted-Pair Internal Cabinet Cable, 100 cm
Product Overview:​ The Honeywell 51304465-300 is a factory-assembled 100 cm (39.4 inch) internal cabinet cable featuring twisted-pair conductors with overall shielding. It is engineered for seamless component interconnection within Honeywell Experion PKS, Process Manager, and TDC 3000 distributed control systems, providing reliable signal transmission and protection against electromagnetic interference.

Detailed content

Key Technical Specifications:
  • Part Number:​ 51304465-300
  • Type:​ Shielded Twisted-Pair Cable Assembly
  • Length:​ 100 cm (39.4 inches)
  • Construction:​ Shielded multi-conductor, industrial-grade insulation
  • Compatibility:​ Experion PKS, Process Manager, TDC 3000 systems
  • Protocol Support:​ HART-compatible signal integrity
  • Operating Temperature:​ -40°C to +85°C (-40°F to +185°F)
  • Compliance:​ RoHS compliant, UL recognized
  • Lifecycle Status:​ Active – OEM production, factory sealed
  • Weight:​ 0.2 kg (0.44 lbs)
  • Country of Origin:​ USA
Functional Features:
  • Twisted-pair conductors reduce crosstalk and noise interference
  • Shielding protects against external EMI/RFI for data integrity
  • Pre-terminated connectors eliminate field wiring errors (reduce commissioning time by up to 40%)
  • Factory-tested impedance matching prevents data corruption
  • Industrial-grade materials resist vibration, moisture, and chemical exposure
Working Principle:​ The cable provides a physical interconnection pathway between DCS components (e.g., C300 controllers to IOTA termination assemblies, or redundant system architectures). The twisted-pair geometry cancels induced noise, while the shield diverts external electromagnetic interference to ground, preserving signal integrity for both analog (4–20 mA/HART) and digital communications.
Application Scenarios:
  • Controller-to-I/O Module Links:​ Connecting C300 controllers to IOTA termination assemblies within control cabinets
  • Redundant System Architectures:​ Facilitating dual-path communication in fault-tolerant configurations
  • Cabinet Retrofit Projects:​ Upgrading legacy TDC 3000 installations to Experion PKS platforms
  • Panel Integration:​ Enabling compact wiring layouts in space-constrained marshalling cabinets
  • Field Junction Box Connections:​ Supporting distributed I/O architectures in oil & gas, chemical processing, and power generation facilities
Installation & Usage Notes:
  • Minimum bend radius: 10× cable diameter (approximately 8 cm) – never splice or extend by coupling multiple units, as this compromises signal integrity and voids UL certification
  • For longer runs, specify factory-assembled 200 cm, 300 cm, or custom configurations
  • Specifically engineered for Honeywell Experion PKS and Process Manager systems; while physical connectors may fit third-party equipment, manufacturer-specified cables are recommended to ensure protocol compatibility and warranty coverage
  • Deploy genuine OEM cables to maintain system warranty coverage and regulatory conformity (critical for retrofit audits in oil & gas, power generation, and chemical processing)

You may also like