GE TFK236175WL
Product Name: General Electric TFK236175WL Molded Case Circuit Breaker.
Product Introduction: This is a premium 175-ampere, 3-pole molded case circuit breaker from GE’s TFK (F225 Line) platform, designed for industrial and commercial electrical systems requiring robust and reliable circuit protection.
Detailed content
Technical Specifications:
- Manufacturer: General Electric
- Frame Type: TFK (F225 Line)
- Poles: 3
- Amperage Rating: 175A
- Voltage Rating: 600V AC max
- Trip Unit: Thermal-magnetic (interchangeable)
- Interrupting Capacity (AIC):
- 25kA @ 240V AC
- 22kA @ 480V AC
- 18kA @ 600V AC
- Dimensions: 4.13 in (W) × 10.13 in (H) × 3.81 in (D)
- Ship Weight: approximately 10 lbs
- Lugs: Line-side and load-side lugs included
- Certifications: UL Listed (UL 489), CSA Certified (CSA C22.2 No. 5-16)
Functional Features: Thermal-magnetic trip unit provides long-time and instantaneous protection against overloads and short circuits; interchangeable trip unit design supports serviceability; high interrupting capacity for fault-tolerant applications; ease of installation with included line and load-side lugs; durable molded case construction for industrial-grade longevity.
Application Scenarios: Heavy-duty industrial and commercial environments; switchboards, panelboards, and power distribution equipment; large equipment protection; complex electrical systems where high interrupting capacity and adaptability are essential.
Structural Characteristics: Molded case construction engineered for long-term durability; thermal-magnetic trip mechanism; includes both line and load-side lugs for secure connections.
Working Principle: The thermal element responds to prolonged overloads by bending a bimetallic strip to trip the mechanism; the magnetic element responds instantaneously to high-magnitude short-circuit currents by energizing a solenoid that trips the breaker — together providing coordinated long-time and instantaneous protection.
Installation Requirements: Install per applicable NEC and local electrical codes; verify the breaker’s AIC rating (25kA@240V / 22kA@480V / 18kA@600V) meets or exceeds the available fault current at the installation point; ensure proper torque on line and load-side lug connections; form-fit-function replacement for compatible TFK-series installations.
Usage Notes: UL 489 and CSA C22.2 No. 5-16 compliant; suitable for commercial, industrial, and institutional power distribution; when replacing in existing TFK-based systems, confirm frame size and trip unit compatibility.