Detailed content
Technical Specifications:
-
Inputs: Bridge temp, fan status, field breaker aux contact
-
Outputs: 8 programmable Form-C relays
-
Architecture: TMR-compatible
-
SOE: Millisecond event stamping
-
Backplane: EX2100e rack
-
Temp: -20 °C to +60 °CFunctional Features: Isolated relay outputs; local sequence-of-events; no active control loop—pure interface; LED per relay.Materials & Structure: FR-4 with conformal coat; plug-on VME-style header; DIN terminal strip.Working Principle: Controller logic asserts optical isolator; transistor drives sealed relay coil; contact closes to annunciator or interposing relay.Installation Requirements: Seat in EX2100e aux slot; ground shield to cubicle; separate thermocouple from relay wires.Precautions: Relay life finite—avoid chatting; verify Form-C common not tied to 125 V DC unprotected.