GE F60U00AKHF8LH6

Product Name: GE Multilin F60 Feeder Protection System — Universal Relay (UR) Family.
Product Introduction: The F60 is a state-of-the-art digital protection relay from GE Vernova’s Multilin UR series, engineered to deliver comprehensive feeder protection, control, and monitoring capabilities for modern distribution networks. The code F60U-00A-KHF8-LH6 denotes a specific configuration variant with 1A/5A current input, 110/220V voltage input, RS-485 (Modbus RTU) and IEC 61850 Ethernet communications, and 85–265V AC/DC auxiliary power.

Detailed content

Technical Specifications:
  • Manufacturer: GE Vernova (Multilin)
  • Series: Universal Relay (UR) Platform
  • Rated Voltage: 48–250V DC / 110–240V AC
  • Current Inputs: 1A or 5A nominal (0.02–46A range)
  • Frequency: 50 Hz / 60 Hz (25–70 Hz range)
  • Measurement Accuracy: ≤0.5% for both current and voltage
  • Communication: RS-485 (Modbus RTU), Ethernet (IEC 61850)
  • Auxiliary Power: 85–265V AC/DC
  • Digital Inputs: 16 configurable
  • Digital Outputs: 14 Form-A relay contacts
  • Operating Temperature: -40°C to +70°C
  • Display: Large full-color LCD with bay mimic, annunciator functionality, and graphical phasor visualization
  • Compliance: IEC 60255, IEEE C37.90, IEEE C37.112, IEC 61850 Ed.1 & Ed.2
Functional Features: Integrated protection functions including overcurrent (50/51), ground protection (50G/51G), differential (87), distance (21), over/under-voltage (27/59), frequency (81), reverse power (32); unique high-impedance fault detection for downed conductor detection; transient ground fault detection (TGFD); flexible load encroachment; routable GOOSE (R-GOOSE) for wide-area protection; phasor measurement unit (synchrophasor) per IEEE C37.118 (2011) and IEC 61850-90-5; fault recording; built-in self-diagnostics; programmable logic.
Application Scenarios: Primary protection and control for feeders on solidly, impedance, or resonant (Petersen coil) grounded systems; bus blocking/interlocking schemes; distribution load shedding; high-speed fault detection for arc flash mitigation; throwover (bus transfer) schemes; backup protection for transmission lines, feeders, and transformers; distributed generation interconnect protection.
Material Composition: Housing in flame-retardant engineering plastic (UL94 V-0); anti-glare polycarbonate front panel; nickel-plated copper alloy terminal blocks; internal FR-4 epoxy glass fiber PCB with conformal coating.
Structural Characteristics: Panel-embedded mounting (1/4 DIN standard); front-panel seal gasket for IP54 (front) protection; rear wiring terminal blocks.
Working Principle: CT/PT signals from the primary system are acquired, converted via A/D, and processed in real time by a DSP. When fault characteristics exceed preset thresholds, the relay drives output contacts to issue trip or alarm signals. IEC 61850 enables high-speed peer-to-peer GOOSE messaging for substation automation.
Usage Notes: Commissioning requires careful setting of protection curves per system coordination study; verify network security configuration for critical infrastructure protection; perform periodic self-test and fault-recorder review.