Digital guide

You are here:

GE DS3800NGRA

  • Product Name: GE Speedtronic Mark IV Regulator / General-Purpose Remote Adapter Board
  • Product Overview: A printed circuit board within the GE Mark IV series for steam/gas turbine management. Depending on configuration, it functions as a computer regulator board or a general-purpose remote adapter providing configurable remote I/O interfaces for distributed control.

Detailed content

  • Technical Specifications:
    • Series: GE Speedtronic Mark IV
    • Board Function: Regulator / Configurable general-purpose remote adapter
    • Central Connector: 28-pin female Augat connector
    • Edge Connectors: Four right-angle PCB mating connectors (218A4637), one P4 and one P6 on each short edge
    • Operating Temperature: 0°C to 60°C (non-condensing)
    • Dimensions: 328 mm × 185 mm × 20 mm (full-length Mark IV board)
    • Backplane Current: +5 V DC @ 0.7 A, +12 V DC @ 0.3 A
    • Components: Analog switches, hex inverters, precision amplifiers, voltage comparators, dual retriggerable monostables; ceramic, polyester film, and fixed vacuum capacitors; ceramic-over-metal-film and carbon-composite resistors
    • Diagnostics: LEDs for Power, Link, Activity, Fault
  • Functional Features: For the regulator role, it conditions and regulates control signals for turbine automation. For the remote adapter role, it provides flexible, configurable remote I/O interfaces adapted to different configurations; communicates with DS3800DMP series CPUs via the Mark IV backplane.
  • Application Scenarios: Mark IV gas and steam turbine management; automated start-up/shut-down; monitoring of water, air, and fuel emissions; distributed remote I/O in turbine control rooms.
  • Installation & Use Notes: Board is factory-drilled and alignment-marked for correct seating in the Mark IV rack. The Mark IV backplane is NOT hot-swappable—power down the cabinet, lock out the breaker, and wait 60 seconds before removal or installation. For remote adapter configurations, photograph jumper settings before removal to replicate on the replacement.