Digital guide

You are here:

GE DS3800HAIC1B1A

Product Name:​ Mark II/III Host Communication Adapter Card
Introduction:​ Legacy serial gateway letting a GE Mark I/II/III turbine controller talk to plant DCS/SCADA via RS-232/485.
Technical Specifications:
  • Interfaces:​ 1 × RS-232 (config), 1 × RS-485 (Modbus RTU/ASCII)

Detailed content

  • Baud Rate:​ 300–115.2 kbps software selectable
  • Protocol:​ Modbus RTU, Modbus ASCII, GE proprietary point-to-point
  • Bus:​ Mark III backplane, through-hole D-sub connectors
  • Temperature:​ 0–60 °C (control-room class)
  • Construction:​ FR-4 2-layer PCB, gold edge fingers, aluminum RF shield
Functional Features:​ On-board UART buffer, jumper-selectable node address, watchdog reset.
Application Scenarios:​ Retrofit comms for vintage gas turbines, historian polling, HMI linkage in older combined-cycle plants.
Notes:​ Static-sensitive; not for direct field-terminal wiring—always land field serial on isolated converter.