Detailed content
Technical Specifications:
-
Input Channels: 16 (configurable subgroups)
-
Signal Types: 3‑wire/4‑wire RTD (100 Ω Pt), 4–20 mA, jumper selectable 0–1 mA
-
Excitation: Isolated 21 VDC sensor supply
-
Filtering: RC network per channel
-
Connections: Screw terminal strip + vertical backplane header
-
Temp: 0–60 °CFunctional Features:
-
Lead‑wire compensation via 3‑wire scheme
-
Onboard jumpers for current vs RTD mode
-
Noise suppression for turbine deckWorking Principle: Provides precision current source to RTD, measures voltage drop, passes conditioned signal to Mark V analog input board.Structure: Narrow PCB, edge terminal block, standoff spacers.Installation: Panel‑mount in TBQA rack, use twisted shielded pair for RTD, ground shield at one end only.Precautions: Mixing 2‑wire sensors on 3‑wire config introduces error; tighten terminals to avoid thermocouple‑like drift.