Detailed content
Technical Specifications:
-
Input: 115–230 VAC (or high‑voltage DC bus derived), polarity protected
-
Logic Outputs: +5 VDC ±3 %, +3.3 VDC ±3 %
-
Current: 0.5–5 A, max ≈26.5 W
-
Field I/O: Motor field supply, tachometer input, SCR pulse output
-
Temp: −40 to +70 °C
-
Dimensions: ≈135 × 99 × 56 mm, 0.34 kgFunctional Features:
-
Integrates power transform, snubber, fuse protection
-
Conditions armature feedback and field current
-
Drives six‑pulse SCR bridge gatesWorking Principle: Steps down and regulates cabinet AC to logic DC, shapes firing pulses from Mark V to thyristor gates, returns armature/tach feedback to controller.Materials: Industrial FR‑4, metal heat spreader, ceramic fuses, optoisolators.Installation: Mount in Mark V drive bay, align with DC2000 ribbon/terminal interface, check fuse rating before energize.Precautions: SCR gate leads are noise‑sensitive; never run without shielding; verify field polarity or risk reverse‑bias damage.