Digital guide

You are here:

GE DS200MBHAG1A

Product Name: GE Multi-Bus Communication & I/O Hub Module (Mark VIe Series Compatible)
Product Introduction: The DS200MBHAG1A is a multi-bus translation module that eliminates the need for multiple single-protocol gateways. It simplifies integration of legacy and modern systems, translating data between different buses and sending a unified stream to the Mark VIe CPU.

Detailed content

Technical Specifications:
  • Manufacturer: General Electric (GE) Industrial Automation
  • Supported Communication Buses: DLAN+ (10 Mbps), DLAN (2 Mbps), Genius (1 Mbps), Modbus RTU (RS-485, 9600-115200 bps), SPI (Mark VIe backplane, 1 Mbps)
  • I/O Configuration: 16 digital inputs (24 V DC sinking/sourcing, <1 ms response); 8 digital outputs (24 V DC, 2 A per channel); 4 analog inputs (4-20 mA, 12-bit resolution)
  • Data Processing: 32-bit embedded microprocessor; 128 KB non-volatile memory; 512 KB RAM
  • Communication Redundancy: DLAN+ dual-port redundancy (auto-failover <100 ms)
  • Power Requirements: 24 V DC from Mark VIe backplane; 0.6 A typical, 0.9 A peak
  • Dimensions (H×W×D): 150 mm × 110 mm × 35 mm; Weight: 280 g
  • Operating Temperature: -30 °C to +70 °C (ambient); -40 °C to +85 °C (short-term storage, <72 h)
  • Certifications: CE, UL 508C, IEC 61010-1, ATEX Zone 2, IEC 61508 (SIL 2 Compatible)
  • Compatibility: GE Mark VIe Control Systems; GE IC698CPE040-FJGE (CPU); GE DS200DACAG1A (D/A module); Legacy DLAN/Genius bus devices; Industrial sensors/actuators
    Functional Characteristics:
  • Multi-bus translation: supports five buses, simplifying legacy-modern integration
  • DLAN+ redundancy: dual-port failover in <100 ms, critical for systems where downtime costs exceed $10,000 per hour
  • Integrated I/O: processes local I/O data before sending aggregated insights to the Mark VIe CPU, cutting SPI backplane traffic by 45%
  • Bus health monitoring (error rate, latency) and I/O fault detection (open/short circuits)
    Structural & Material Features:
  • Slot-mount form factor
  • Conformal-coated PCB (moisture/dust resistance)
  • ESD protection (±15 kV contact)
  • EMI shielding (EN 55022 Class A)
    Working Principle: The module translates data between DLAN+, DLAN, Genius, and Modbus RTU buses, then sends a unified stream to the Mark VIe CPU. Local I/O is processed on-board before aggregated data is transmitted, reducing backplane traffic.
    Application Scenarios:
  • Chemical plants with mixed legacy Genius sensors and new DLAN+ drives
  • Gas turbine plants requiring uninterrupted communication
  • Water treatment plants monitoring pump status and chemical levels
    Usage Notes:
  • Auto-failover ensures zero communication loss during bus faults
  • Diagnostic features enable bus health monitoring and I/O fault detection

You may also like