GE DS200LDCCG1AAA
Product Name: GE DIRECTO-MATIC 2000 Drive Control / LAN Communications Board
Product Overview: The DS200LDCCG1AAA is a Drive Control and LAN Communications Board designed for integration into GE DIRECTO-MATIC 2000 drives and exciters. Developed by GE Motors & Industrial Systems, this board provides core processing functions and LAN communication capabilities for industrial motor control applications.
Detailed content
Technical Specifications:
- Manufacturer: GE Motors & Industrial Systems
- Series: DIRECTO-MATIC 2000 / EX2000
- Model Number: DS200LDCCG1AAA
- Product Type: Drive Control / LAN Communications Board
- Functional Acronym: LDCC
- Instruction Manual: GEI-100216
- PCB Coating: Normal coating (Group G1)
- Functional Revisions: Functional Revision 1: A; Functional Revision 2: A; Artwork Revision: A
- Power Requirement: +5 V DC, 7 A
- Power Consumption: Approximately 20 W
- Operating Temperature: -10 °C to +60 °C
- Isolation Voltage: 1,500 V AC
Microprocessor Architecture: The board includes four key onboard processors, each assigned to specific control tasks:
- DCP (Drive Control Processor) at U1: Manages I/O functions, analog/digital signal conversions
- MCP (Motor Control Processor) at U21: Controls digital I/O and motor operation
- CMP (Co-Motor Processor) at U35: Assists MCP with high-complexity computations
- LCP (LAN Control Processor) at U18: Manages LAN communication
Supported Bus Systems: DLAN+, DLAN, Genius, CPL, C-bus
Functional Features:
- Acts as the primary control and communications processor board for GE DIRECTO-MATIC drive and excitation systems
- Handles drive control, motor processing, I/O handling, and LAN communications through dedicated onboard processors
- Integrates drive regulation, LAN communications, diagnostics, and application execution
- Performs motor control, I/O processing, and analog/digital signal conversion
- Supports LAN (Local Area Network) communication
Application Scenarios: AC/DC drive systems, excitation systems, industrial motor control applications, power generation automation.
Installation Note: During outages, it is strongly recommended to match the full DS200LDCCG1AAA revision rather than assuming any LDCC board will work.