Digital guide

You are here:

B&R 4C2210.01-510

Material Composition:

Conductors are fine-stranded Class 5 copper per IEC 60228 (560 strands of 0.20 mm diameter each) for maximum flexibility. Insulation is cross-linked polyethylene (XLPE) rated to 90°C continuous. The PUR outer jacket provides exceptional resistance to cutting oils, hydraulic fluids, coolants, and mechanical abrasion — critical for servo motor environments in CNC and machining centers.

Detailed content

Core Technical Specifications:

Parameter Value
Conductor Cross-Section 10 mm² (AWG 7 equivalent)
Number of Conductors 4 (3 phases U/V/W + PE)
Voltage Rating (U0/U) 300/500 V (AC) / 750 V (DC)
Cable Type 4C2210 — Servo-rated, double-shielded, PUR-sheathed
Outer Sheath Material PUR (Polyurethane) — oil & abrasion resistant
Shielding Configuration Overall tinned copper braid (coverage > 85%) + individual pair foil shield
Cable Length 5.0 meters (factory-cut)
Drive-Side Connector M23 17-pin male (straight, screw-lock)
Motor-Side Connector M23 12-pin female (straight, pre-crimped)
Pin Assignment (Drive Side) Pins 1–3: U/V/W power, Pin 4: PE, Pins 5–8: Encoder signals, Pins 9–17: Reserved/auxiliary
Color Coding Brown (U), Black (V), Gray (W), Green/Yellow (PE)
Current Rating ~47 A (installation method B, IEC 60364-5-52)
Minimum Bend Radius (Fixed) 5 × cable OD ≈ 75 mm
Minimum Bend Radius (Flexible) 6 × cable OD ≈ 90 mm
Ambient Temperature (Fixed) -5°C to +70°C
Ambient Temperature (Flexible) -15°C to +70°C
Fire Behavior Flame-retardant per IEC 60332-1-2

Functional Features:

Factory-assembled connectors with crimp-and-seal technology ensure IP67 connector integrity when mated. Double shielding provides > 60 dB EMC attenuation in the 150 kHz–30 MHz range, fully compliant with EN 61800-3 (EMC for adjustable speed drives). The cable is UL listed and CSA certified for North American installations.

Applicable Industries:

ACOPOS and ACOPOSmulti servo motor connections, CNC machine tool axis drives, robot arm servo feeds, injection molding machine servo axes, printing press drive connections.

Installation Requirements:

Route in cable carrier (drag chain) or conduit. Maintain minimum 100 mm separation from 400 V+ power cables. Secure with cable clamps every 0.5 m along tray runs. Ensure connectors are fully threaded and locked before applying power. Ground the cable shield at both ends to the drive and motor chassis.

Critical Usage Directives:

Never cut or modify cable length in the field. Do not use with non-B&R servo systems without verifying pin compatibility. Inspect connectors for corrosion or pin damage every 6 months. Replace immediately if PUR jacket shows cuts, cracks, or chemical degradation. Maximum continuous operating temperature at conductor: 90°C.