BAUMÜLLER BM4424-AT1-012 42-03311-7012 Synchronous Servo Motor
Product Introduction:
The BAUMÜLLER BM4424-AT1-012 42-03311-7012 is a customized large-frame servo motor from the BM4424 family with forced air cooling, keyed shaft with seal, rotatable connector, 4-pole winding, and customer-specific modification code 42-03311-7012. This variant differs from Entry 08 (42-0311-7012) in specific modification parameters encoded in the 42-03311-7012 identifier.
Detailed content
Cooling Method: Forced Air Cooling (A) — Integral fan-driven cooling for continuous high-power operation.
Shaft Configuration: Keyed Shaft with Radial Shaft Seal (T) — DIN 6885-1 keyway with single radial seal on drive end.
Electrical Connection: Rotatable Connector (1) — M23, 360° rotation.
Pole Configuration: 012 = 2 Pole Pairs (4 Poles)
Frame Size: 280 mm Flange Diameter
Motor Length Code: 24 (Long Length) — Overall length approximately 340–400 mm (excluding shaft).
Rated Torque: Approximately 25–50 Nm
Peak Torque: Up to 3× Rated Torque
Rated Power: Approximately 10–22 kW
Maximum Rated Speed: Up to 3000–4000 rpm
Protection Class: IP54 / IP55 (with forced cooling and shaft seal)
Insulation Class: Class F (155°C)
Ambient Temperature Range: -10°C to +40°C (continuous); up to +50°C with forced cooling.
Housing Material: Aluminum Alloy Die-Cast (ADC12) with Integral Cooling Fins and Fan Shroud
Stator Lamination: 0.35 mm Grain-Oriented Silicon Steel
Rotor Magnets: Sintered NdFeB N42SH / N42UH
Bearings: Deep Groove Ball Bearing (Drive End) + Cylindrical Roller Bearing (Non-Drive End)
Shaft Material: Induction-Hardened C45E (1.0503)
Shaft Diameter: 55 mm or 70 mm
Keyway: DIN 6885-1 Form A
Weight: Approximately 55–85 kg
Moment of Inertia: Approximately 0.080–0.250 kg·m²
Custom Code 42-03311-7012: BAUMÜLLER internal modification identifier — Distinct from 42-0311-7012; encodes specific customer-requested variations in mechanical dimensions, electrical parameters, connector configuration, coating, encoder type, or special features.
Encoder Options: As specified in 42-03311-7012 — typically EnDat 2.2, Hiperface DSL, or BiSS-C absolute encoders
Standards Compliance: EN 60034-1, EN 60034-5, EN 60034-6 (IC 416), EN 61800-5-1, CE, UL, CSA (optional)
Applicable Industries: Same as BM4424-AT1-012 base — Heavy Industry, CNC, Mining, Ship Propulsion, Wind Energy, Steel Mills — with modifications per 42-03311-7012
Key Advantages:
- Identical base performance to BM4424-AT1-012
- Custom code 42-03311-7012 provides specific application optimization distinct from 42-0311-7012
- Forced air cooling ensures continuous rated power in enclosed installations
- 280 mm frame provides high torque for heavy-duty applications
- Large shaft (55/70 mm) enables direct coupling to heavy machinery
Installation Requirements:
- B5 flange mounting — 4× M12/M16 on 280 mm PCD.
- Minimum 300 mm clearance on fan side for airflow.
- Alignment: ≤0.05 mm radial, ≤0.05 mm axial, ≤0.5° angular.
- Verify all 42-03311-7012 modifications against drawing package.
Operating Notes:
- Do not operate without forced cooling fan running.
- Refer to 42-03311-7012 documentation for any modified operating limits.
- Bearing inspection interval: every 4000 operating hours or 12 months.