Digital guide

You are here:

Atlas Copco TC-52P-N

Product Introduction:
The TC52P-N is the VSD premium variant of the TC52 frame without an integrated air dryer. The “N” suffix confirms no dryer is included. This model is designed for facilities that already have a central dryer system or require a specific dryer type (refrigerated, desiccant, membrane) to be selected and installed separately. The PM variable speed drive provides full load modulation from 100% down to 25%.

Detailed content

Technical Specifications:

Parameter Value
Model TC-52P-N
Compressor Type Oil-injected rotary screw, VSD
Drive Type Permanent Magnet (PM) Variable Speed Drive
Free Air Delivery (FAD) 42.4 m³/min (1,500 CFM) at 7 bar (100% speed)
Turndown Ratio 100% to 25%
Maximum Working Pressure 10 bar (1,000 kPa / 145 psi) — standard; up to 13 bar optional
Rated Motor Power 55 kW (75 hp) — IE4
Motor Efficiency Class IE4 (Super Premium Efficiency)
Voltage / Frequency / Phase 400V / 50Hz / 3-phase (Code 81)
Cooling Method Air-cooled
Sound Power Level 69 dB(A) at 75% load
Controller Elektronikon Mk5 with VSD
Dimensions (L×W×H) Approx. 1,800 × 1,100 × 1,400 mm
Weight (Dry) Approx. 1,050 kg

Material Composition:

  • Rotor Housing: Cast iron GG25
  • Rotors: Atomized alloy steel, 50 HRC
  • PM Motor: Neodymium permanent magnets, IE4 rated
  • Oil Separator: Glass fiber coalescing media
  • Cooler: Aluminum plate-fin

Structural Features:

  • Identical compressor end to TC52P-M but without dryer vessels
  • Smaller overall footprint (no dryer towers)
  • VSD inverter integrated in canopy
  • Elektronikon Mk5 controller with demand-based speed control

Working Principle:
PM motor varies speed to maintain setpoint pressure. At partial load, the compressor runs at reduced speed, consuming significantly less power. The affinity laws dictate that a 50% speed reduction yields approximately 87.5% power reduction (0.5³ = 0.125 of full-load power).

Key Advantages:

  • 35% energy savings vs. fixed-speed alternative
  • Compact footprint — no dryer occupies space
  • Flexibility to pair with any dryer type (refrigerated, desiccant, membrane)
  • Lower initial cost than TC52P-M (no dryer included)

Applicable Industries:
Facilities with centralized compressed air treatment, manufacturing, printing, textiles, general industry.

Installation Requirements:

  • Indoor, 1.5 m clearance minimum
  • Ambient: 0°C to +45°C
  • Floor load: 1,200 kg
  • Electrical: 400V/50Hz/3-phase, 100A breaker
  • Must install downstream dryer — minimum 3 m straight pipe between compressor and dryer

Usage Notes:

  • Oil change: 8,000 hours or 2 years
  • Air filter: every 4,000 hours
  • Oil separator: every 8,000 hours
  • Without a dryer, discharge air will contain moisture — install refrigerated dryer (dew point +3°C) or desiccant dryer as required by application