Atlas Copco PF3007-G-DN-HW

Product Series: PF3007 Series — Generator-Equipped Portable Compressor (Generation 7)

Product Introduction: The PF3007-G-DN-HW combines a 30 m³/min screw compressor with an integrated diesel-driven generator. The “G” indicates generator-equipped configuration. The “DN” denotes diesel-driven (standard diesel power train). The “HW” suffix provides high-altitude operational capability. This unit is a self-contained power and air station.

Detailed content

Technical Specifications:

Parameter Value
Free Air Delivery (FAD) 30.0 m³/min (1,059 cfm)
Working Pressure Range 7 – 13 bar (101 – 188 psi)
Rated Pressure 13 bar (188 psi)
Engine Model (Compressor) Deutz TCD 2013 L04 2V
Engine Power (Compressor) 247 kW (331 hp)
Generator Model Stamford / Leroy-Somer
Generator Power Output 200 kVA / 160 kW (50 Hz)
Generator Voltage 400V / 230V, 3-phase, 50 Hz
Compressor Element Atlas Copco GA rotary screw airend
Cooling System Air-cooled
Fuel Tank Capacity 600 L (159 US gal)
Operating Weight 10,200 kg (22,487 lbs)
Dimensions (L×W×H) Approx. 5,400 × 2,200 × 2,500 mm
Noise Level (at 7m) ≤ 96 dB(A)
Emissions Compliance EPA Tier 4 Final / EU Stage V

Material Composition:

  • Chassis: S355 hot-dip galvanized steel
  • Generator Enclosure: Sound-attenuated steel housing
  • Alternator: 100% copper windings, Class H insulation
  • Airend: Cast iron housing, steel rotors

Structural Features:

  • Single-axle trailer with hydraulic jacks
  • Dual canopy: compressor section + generator section
  • Integrated circuit breaker panel on exterior
  • Forklift pockets on all four corners

Working Principle: The Deutz diesel engine simultaneously drives the screw airend (via coupling) and the alternator (via belt drive or PTO). The generator produces 400V 3-phase power for external tools, lighting, or auxiliary equipment while the compressor delivers pressurized air. Both systems operate from a single fuel source.

Key Advantages:

  • Self-contained air + power station eliminates need for separate generator
  • 200 kVA output powers multiple heavy tools simultaneously
  • Single fuel tank serves both engine and generator
  • HW-rated for high-altitude sites

Applicable Industries: Remote construction sites, mining camps, events, road building, drilling rigs with no grid power

Installation Requirements:

  • Flat ground with ≥ 12 tonnes/m² capacity
  • 3m clearance on generator side for exhaust dispersion
  • Earth grounding rod required for electrical safety

Usage Precautions:

  • Monitor generator load — do not exceed 160 kW continuous
  • Check alternator belt tension every 250 hours
  • Use only Atlas Copco-approved fuel filters
  • Never operate generator and compressor at full load simultaneously without derating