Atlas Copco PF3007-G-DN-HW
Product Series: PF3007 Series — Generator-Equipped Portable Compressor (Generation 7)
Product Introduction: The PF3007-G-DN-HW combines a 30 m³/min screw compressor with an integrated diesel-driven generator. The “G” indicates generator-equipped configuration. The “DN” denotes diesel-driven (standard diesel power train). The “HW” suffix provides high-altitude operational capability. This unit is a self-contained power and air station.
Detailed content
Technical Specifications:
| Parameter | Value |
|---|---|
| Free Air Delivery (FAD) | 30.0 m³/min (1,059 cfm) |
| Working Pressure Range | 7 – 13 bar (101 – 188 psi) |
| Rated Pressure | 13 bar (188 psi) |
| Engine Model (Compressor) | Deutz TCD 2013 L04 2V |
| Engine Power (Compressor) | 247 kW (331 hp) |
| Generator Model | Stamford / Leroy-Somer |
| Generator Power Output | 200 kVA / 160 kW (50 Hz) |
| Generator Voltage | 400V / 230V, 3-phase, 50 Hz |
| Compressor Element | Atlas Copco GA rotary screw airend |
| Cooling System | Air-cooled |
| Fuel Tank Capacity | 600 L (159 US gal) |
| Operating Weight | 10,200 kg (22,487 lbs) |
| Dimensions (L×W×H) | Approx. 5,400 × 2,200 × 2,500 mm |
| Noise Level (at 7m) | ≤ 96 dB(A) |
| Emissions Compliance | EPA Tier 4 Final / EU Stage V |
Material Composition:
- Chassis: S355 hot-dip galvanized steel
- Generator Enclosure: Sound-attenuated steel housing
- Alternator: 100% copper windings, Class H insulation
- Airend: Cast iron housing, steel rotors
Structural Features:
- Single-axle trailer with hydraulic jacks
- Dual canopy: compressor section + generator section
- Integrated circuit breaker panel on exterior
- Forklift pockets on all four corners
Working Principle: The Deutz diesel engine simultaneously drives the screw airend (via coupling) and the alternator (via belt drive or PTO). The generator produces 400V 3-phase power for external tools, lighting, or auxiliary equipment while the compressor delivers pressurized air. Both systems operate from a single fuel source.
Key Advantages:
- Self-contained air + power station eliminates need for separate generator
- 200 kVA output powers multiple heavy tools simultaneously
- Single fuel tank serves both engine and generator
- HW-rated for high-altitude sites
Applicable Industries: Remote construction sites, mining camps, events, road building, drilling rigs with no grid power
Installation Requirements:
- Flat ground with ≥ 12 tonnes/m² capacity
- 3m clearance on generator side for exhaust dispersion
- Earth grounding rod required for electrical safety
Usage Precautions:
- Monitor generator load — do not exceed 160 kW continuous
- Check alternator belt tension every 250 hours
- Use only Atlas Copco-approved fuel filters
- Never operate generator and compressor at full load simultaneously without derating