Digital guide

You are here:

Atlas Copco PF3007-AG-G

Product Introduction:
The PF3007-AG-G is a portable electric air compressor featuring an integrated generator (AG) and electric motor drive (G). The “A” denotes automatic control system, “G” denotes electric drive, and the generator package provides self-contained power generation for the compressor and auxiliary tools at remote sites without grid access.

Detailed content

Technical Specifications:

  • Free Air Delivery (FAD): 300 CFM (8.5 m³/min) at 100 PSI (7 bar)
  • Maximum Working Pressure: 175 PSI (12 bar)
  • Drive Type: Electric Motor — 75 kW (100 HP)
  • Generator: Integrated diesel generator — 110 kVA / 88 kW
  • Engine (Generator): Volvo/Perkins Tier 4 Final — 110 kW
  • Fuel Tank Capacity (Generator): 250 liters (66 US gallons)
  • Operating Weight: Approximately 3,500 kg (7,716 lbs)
  • Dimensions (L × W × H): Approximately 4,000 × 1,800 × 2,100 mm
  • Noise Level: 98 dB(A) at 7 meters

Functional Features:

  • Auto Control (A): Automatic start/stop based on air demand; pressure band control
  • Generator Package (AG): Self-contained power supply — runs compressor and auxiliary equipment
  • Electric Drive (G): Zero local emissions from compressor operation
  • Integrated Control System: PLC-based controller with remote monitoring capability

Performance Parameters:

Parameter Value
FAD @ 100 PSI 300 CFM (8.5 m³/min)
FAD @ 40 PSI 460 CFM (13.0 m³/min)
Max Pressure 175 PSI (12 bar)
Compressor Motor 75 kW (100 HP)
Generator Output 110 kVA / 88 kW
Generator Fuel Consumption Approximately 22 L/hr at 75% load
Duty Cycle 100% continuous

Material Composition:

  • Frame: Structural steel with anti-corrosion primer and topcoat
  • Air End: Cast iron two-stage rotary screw
  • Tank: ASME / PED certified carbon steel vessel
  • Generator Enclosure: Sound-attenuated steel canopy

Structural Characteristics:

  • Single-axle trailer with pneumatic tires and air brakes
  • Integrated generator mounted on same chassis as compressor
  • Centralized control cabinet with weatherproof enclosure
  • Dual forklift pockets and four lifting eyes

Working Principle:
The integrated diesel generator produces electrical power that drives the electric compressor motor. The auto control system monitors downstream pressure and automatically starts/stops the compressor to maintain the set pressure band (typically 116–175 PSI). Air is compressed in two stages, intercooled, and delivered through standard aftercooling.

Advantage Highlights:

  • Fully self-contained — no external power or separate generator needed
  • Automatic pressure management reduces fuel consumption by 20–30% vs. continuous run
  • Electric compressor drive eliminates compressor-side emissions and engine maintenance
  • Ideal for rental fleets requiring plug-and-play deployment

Applicable Industries:
Rental companies, construction, event support, painting, sandblasting, remote industrial maintenance, telecom tower work

Model Series: PF3007 Series — Portable Compressors with Generator (250–350 CFM range)

Installation Requirements:

  • Level ground surface; no external power connection needed
  • Minimum 1.5-meter clearance on all sides for cooling airflow
  • Generator exhaust must have minimum 1-meter clearance from obstacles

Usage Precautions:

  • Run generator at 50–75% load for optimal fuel efficiency
  • Check generator oil level before each shift
  • Compressor auto-start may cause voltage dip — verify generator sizing matches motor inrush current
  • Service both generator and compressor filters on a unified schedule