Digital guide

You are here:

AEG MM-PMA2-300

Product Name: AEG MM-PMA2-300 Power Supply Module / Power Management Unit

Product Series: MM-PMA2 Series Power Modules

Product Type: DIN Rail Mounted Switched-Mode Power Supply (SMPS)

Input Voltage85 – 264 V AC (universal input), 47 – 63 Hz

Detailed content

Output Voltage: 24 V DC (adjustable: 21 – 28 V DC via trim pot)

Rated Output Current: 12.5 A

Rated Output Power300 W

Output Ripple (P-P)≤ 100 mV (at full load, 20 MHz bandwidth)

Efficiency: ≥ 91% (at 230 V AC input, full load)

No-Load Power Consumption: ≤ 0.5 W

Hold-Up Time: ≥ 20 ms at full load (at 230 V AC)

Output Adjustment Range: 21 V to 28 V DC (continuous)

Protection Functions:

  • Short circuit protection: Auto-recovery, hiccup mode
  • Overload protection: 110%–150% rated current, auto-recovery
  • Overvoltage protection: 31 V DC (latch-off, auto-recovery after fault removal)
  • Overtemperature protection: 85°C (derating from 70°C)

Number of Outputs1 (single output)

MTBF≥ 100,000 hours (at 25°C, full load)

Operating Temperature-25°C to +70°C (with full load derating above 50°C)

Cooling: Forced air convection (built-in fan, 40 mm × 40 mm)

Protection ClassIP20 (open frame); IP40 (with optional cover)

StandardsIEC 62368-1, EN 62368-1, UL 62368-1, CE, RCM

Housing MaterialAluminum die-cast with powder coating (RAL 7035 light gray)

Dimensions (W × H × D): 125 mm × 127 mm × 54 mm

Weight: 1.1 kg

Mounting35 mm DIN rail (EN 60715, TS 35/7.5 or TS 35/15)

Key Features:

  • Active PFC (Power Factor Correction): ≥ 0.99 at full load
  • Parallel operation capable (up to 4 units with current sharing)
  • Remote ON/OFF control via dry contact input
  • LED indicators: Power (green), Fault (red), Output OK (green)

Applicable Industries: PLC/HMI power supply, CNC machine control, robotics, industrial PCs, LED lighting systems, security systems

Installation Requirements:

  • Mount vertically with fan facing up for optimal airflow
  • Leave minimum 50 mm clearance above and below for ventilation
  • Input fuse required: 6 A slow-blow (T6A) at 230 V AC
  • Output cable: minimum 4 mm² copper for 12.5 A continuous current

Usage Notes:

  • Derate output current by 3.5% per °C above 50°C ambient
  • Do not block fan intake or exhaust — causes thermal shutdown
  • Parallel operation requires external current-sharing modules (sold separately)
  • Perform output voltage trim at commissioning to exact required value