Digital guide

You are here:

ABB UUD148AE01 3BHE014185R0001

Product Name​
UUD148AE01 Voltage Transducer Interface Board
Product Introduction​
Signal acquisition and conditioning board for ABB PCS6000 medium-voltage drives and AC 800PEC power electronics platforms. Collects voltage and current transducer signals from the power section, isolates and digitizes them for main control feedback.

Detailed content

Technical Specifications​
  • Board Type: Voltage/current transducer interface board
  • Compatible Systems: PCS6000, AC 800PEC
  • Supply Voltage: 24 V DC
  • Power Consumption: 3 W to 15 W depending on configuration
  • Dimensions: approximately 132 × 105 × 52 mm
  • Weight: approximately 1.2 to 1.44 kg
  • Signal Type: Voltage and current transducer input
  • Output: Isolated digital feedback to controller
  • Coating: Conformal-coated PCB
  • Operating Temperature: industrial cabinet environment rating
Functional Features​
  • High-resolution voltage and current signal conversion
  • Electrical isolation between power and control sides
  • Built-in EMC filtering
  • Noise suppression for high-interference environments
  • Real-time torque and power feedback
  • Direct mechanical replacement in compatible racks
Application Scenarios​
  • Mine hoist drives
  • Wind farm converters
  • Large synchronous and asynchronous motor control
  • High-power industrial inverter systems
  • Critical process drive backup and retrofit
Structural Characteristics​
  • Metal-enclosed signal processing board
  • Conformal-coated circuit assembly
  • Cabinet rack mounting
  • Industrial connectors
  • Shielded signal paths
Working Principle​
Transducer signals from the power unit are filtered, isolated, and converted into digital values. The controller uses this data for voltage regulation, torque control, and synchronization.
Installation Requirements​
  • Install only in de-energized power cabinet
  • Confirm pairing with UUD148AE02 if required
  • Check connector orientation and rack slot
  • Verify 24 V DC auxiliary supply
  • Perform signal calibration after replacement
Usage Precautions​
  • Discharge capacitors before handling
  • Avoid damaging conformal coating
  • Do not substitute unsupported hardware revision
  • Check synchronization and transducer fault logs after restart