Digital guide

You are here:

ABB UFC911B104 3BHE037864R0104

Product Name​
UFC911B104 CVMI2B Voltage Measurement Interface Board
Product Introduction​
Voltage sensing board for ABB ACS5000 medium-voltage drives. Samples AC phase voltage and DC bus voltage from power cells, performs isolation and signal conversion, and sends measurement data to the main controller.

Detailed content

Technical Specifications​
  • Board Type: Voltage measurement interface board
  • Compatible System: ACS5000 medium-voltage drive
  • Model Designation: UFC911B104 / CVMI2B
  • Auxiliary Supply: 24 V DC
  • Measurement Object: AC voltage, DC bus voltage
  • Signal Processing: High-voltage isolation, A/D conversion
  • Protection Functions: Overvoltage and undervoltage monitoring
  • Net Weight: approximately 0.3 kg
  • Operating Temperature: -20 to +70 °C
  • Storage Temperature: -40 to +85 °C
  • Protection Rating: IP20 in power cell cabinet
  • Standards: CE, IEC 61800
Functional Features​
  • High-voltage resistive isolation
  • Accurate bus voltage sampling
  • Overvoltage and undervoltage fault detection
  • Hardware-level diagnostics
  • Direct communication with main control board
  • Slot-based installation in power cell
Application Scenarios​
  • ACS5000 medium-voltage frequency converters
  • Power plant fan and pump drives
  • Cement main drives
  • Metallurgy and oil/gas motor systems
  • Large high-voltage inverter power units
Structural Characteristics​
  • Slot-mounted PCB assembly
  • Galvanic isolation components
  • Precision voltage divider network
  • Industrial connector interface
  • Compact lightweight board structure
Working Principle​
High-voltage signals are attenuated and isolated, then converted into low-voltage digital values. The controller uses the data for voltage regulation, protection, and fault diagnosis.
Installation Requirements​
  • Perform full discharge of power cell before service
  • Insert into designated ACS5000 slot
  • Verify board version and connector alignment
  • Recheck calibration after installation
  • Confirm compatibility with CVMI2 series revision
Usage Precautions​
  • CVMI2B cannot directly replace CVMI2A
  • Do not bypass isolation barriers
  • Calibrate voltage feedback before commissioning
  • Replace if sampling drift or communication loss occurs