ABB LT2005-S/SP19 3BHB014827R0001
Product Name
LT2005-S/SP19 Current Transducer
Product Introduction
Closed-loop Hall-effect current transducer designed for high-power drive systems. Primarily used in ABB ACS6000 medium- and high-voltage frequency converters for main circuit current measurement and overcurrent protection.
Detailed content
Technical Specifications
- Technology: Closed-loop Hall effect
- Primary Rated Current: 2000 A RMS
- Measuring Range: 0 to ±3000 A
- Secondary Rated Current: 400 mA RMS
- Transformation Ratio: 1:5000
- Supply Voltage: ±15 V to ±24 V DC, ±5% tolerance
- Accuracy: ±0.3% at 25 °C
- Linearity Error: <0.1%
- di/dt Capability: 100 A/µs
- Bandwidth: 100 kHz
- Response Time: <1 µs
- Overload Capacity: 3 times rated current
- Insulation: Primary/secondary electrical isolation
- Operating Temperature: -10 to +70 °C
- Storage Temperature: -25 to +85 °C
Functional Features
- High-precision DC, AC, and pulse current measurement
- Full electrical isolation between power and control circuits
- Fast dynamic response
- Strong overload resistance
- Low temperature drift
- Compatible with high-power inverter control systems
Application Scenarios
- ACS6000 medium-voltage drives
- Rolling mill main drives
- Large fan and pump systems
- Rectifiers and inverters
- Industrial power test platforms
Material Composition
- Flame-retardant plastic housing, UL 94-V0 grade
- Epoxy-sealed magnetic core
- Precision Hall sensor
- Copper primary conductor path
- Industrial connector terminals
Structural Characteristics
- Panel or busbar mounting style
- Through-hole primary conductor design
- Shielded signal output
- Heavy-duty industrial enclosure
- Approximate weight 1.86 kg
Working Principle
The transducer uses Hall-effect closed-loop compensation. The magnetic field generated by the primary current is measured and compensated by a secondary current that accurately represents the primary current.
Installation Requirements
- Install with correct primary current direction
- Use torqued busbar connections
- Keep signal cables separated from power cables
- Provide stable bipolar auxiliary power
- Ensure adequate ventilation and cooling
Usage Precautions
- Never exceed insulation and overload ratings
- Avoid mechanical stress on terminals
- Calibrate zero offset before commissioning
- Verify SP19 customization compatibility with target drive